Treatment of Displaced Olecranon Fractures: A Systematic Review

dc.contributor.authorRantalaiho I.
dc.contributor.authorMiikkulainen A.
dc.contributor.authorLaaksonen I.
dc.contributor.authorÄärimaa V.
dc.contributor.authorLaimi K.
dc.contributor.organizationfi=fysiatria|en=Physical and Rehabilitation Medicine|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.17712075286
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607320
dc.converis.publication-id44151895
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/44151895
dc.date.accessioned2022-10-28T12:46:00Z
dc.date.available2022-10-28T12:46:00Z
dc.description.abstract<div><div><h2>Background and Aims:</h2></div><p>The incidence of olecranon fractures is rising. Displaced fractures are usually operated either by tension band wiring or plate fixation. The aim of this review is to evaluate the best current evidence on the management of displaced olecranon fractures.</p></div><div><a></a><div><h2>Materials and Methods:</h2></div><p>Randomized controlled trials were systematically gathered in May 2018 from CENTRAL, MEDLINE, Embase, CINAHL, Scopus, and PEDro databases. The methodological quality of articles was assessed according to the Cochrane Collaboration’s domain-based framework. Prospero database registration number: CRD42018096650.</p></div><div><a></a><div><h2>Results:</h2></div><p>Of 1518 identified records, finally, 5 were relevant. Four trials were found on tension band wiring: two compared tension band wiring with plate fixation (n = 108), one compared plate fixation with an olecranon memory connector (n = 40), and one trial compared tension band wiring with a modified tension band wiring called Cable Pin System (n = 62). In addition, one trial compared operative and conservative treatment in elderly (n = 19). The risk of bias was considered low in two and high in three of the trials. The follow-up time was 5–36 months, and outcome measures varied from patient-rated and physician-rated measures to radiological outcomes. In the analysis, there was no difference between tension band wiring and plate fixation. The data were insufficient for further quantitative analysis.</p></div><div><a></a><div><h2>Conclusion:</h2></div><p>No differences were found in clinical or patient-rated outcome measures between the two most frequent fixation methods (tension band wiring and plate fixation) of displaced olecranon fractures. Current data are not sufficient to evaluate other treatment methods; however, conservative treatment might serve as an option for selected patients in the elderly population.</p></div>
dc.identifier.jour-issn1457-4969
dc.identifier.olddbid178804
dc.identifier.oldhandle10024/161898
dc.identifier.urihttps://www.utupub.fi/handle/11111/51696
dc.identifier.urlhttps://doi.org/10.1177/1457496919893599
dc.identifier.urnURN:NBN:fi-fe2021042826475
dc.language.isoen
dc.okm.affiliatedauthorRantalaiho, Ida
dc.okm.affiliatedauthorMiikkulainen, Annika
dc.okm.affiliatedauthorLaaksonen, Inari
dc.okm.affiliatedauthorÄärimaa, Ville
dc.okm.affiliatedauthorLaimi, Katri
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA2 Scientific Article
dc.publisherSAGE Publications Inc.
dc.relation.doi10.1177/1457496919893599
dc.relation.ispartofjournalScandinavian Journal of Surgery
dc.source.identifierhttps://www.utupub.fi/handle/10024/161898
dc.titleTreatment of Displaced Olecranon Fractures: A Systematic Review
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Manuscript_revision.pdf
Size:
762.24 KB
Format:
Adobe Portable Document Format
Description:
Final Draft