A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging

dc.contributor.authorSiekkinen Reetta
dc.contributor.authorHan Chunlei
dc.contributor.authorMaaniitty Teemu
dc.contributor.authorTeräs Mika
dc.contributor.authorKnuuti Juhani
dc.contributor.authorSaraste Antti
dc.contributor.authorTeuho Jarmo
dc.contributor.organizationfi=InFLAMES Lippulaiva|en=InFLAMES Flagship|
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.68445910604
dc.contributor.organization-code1.2.246.10.2458963.20.75985703497
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.converis.publication-id178530507
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/178530507
dc.date.accessioned2025-08-27T22:06:13Z
dc.date.available2025-08-27T22:06:13Z
dc.description.abstract<p><strong>Background: </strong>New Block-Sequential-Regularized-Expectation-Maximization (BSREM) image reconstruction technique has been introduced for clinical use mainly for oncologic use. Accurate and quantitative image reconstruction is essential in myocardial perfusion imaging with positron emission tomography (PET) as it utilizes absolute quantitation of myocardial blood flow (MBF). The aim of the study was to evaluate BSREM reconstruction for quantitation in patients with suspected coronary artery disease (CAD).</p><p><strong>Methods and results: </strong>We analyzed cardiac [<sup>15</sup>O]H<sub>2</sub>O PET studies of 177 patients evaluated for CAD. Differences between BSREM and Ordered-Subset-Expectation-Maximization with Time-Of-Flight (TOF) and Point-Spread-Function (PSF) modeling (OSEM-TOF-PSF) in terms of MBF, perfusable tissue fraction, and vascular volume fraction were measured. Classification of ischemia was assessed between the algorithms. OSEM-TOF-PSF and BSREM provided similar global stress MBF in patients with ischemia (1.84 ± 0.21 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup> vs 1.86 ± 0.21 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup>) and no ischemia (3.26 ± 0.34 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup> vs 3.28 ± 0.34 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup>). Global resting MBF was also similar (0.97 ± 0.12 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup> and 1.12 ± 0.06 g⋅ml<sup>-1</sup>⋅min<sup>-1</sup>). The largest mean relative difference in MBF values was 7%. Presence of myocardial ischemia was classified concordantly in 99% of patients using OSEM-TOF-PSF and BSREM reconstructions CONCLUSION: OSEM-TOF-PSF and BSREM image reconstructions produce similar MBF values and diagnosis of myocardial ischemia in patients undergoing [<sup>15</sup>O]H<sub>2</sub>O PET due to suspected obstructive coronary artery disease.</p>
dc.format.pagerange1602
dc.format.pagerange1612
dc.identifier.eissn1532-6551
dc.identifier.jour-issn1071-3581
dc.identifier.olddbid201643
dc.identifier.oldhandle10024/184670
dc.identifier.urihttps://www.utupub.fi/handle/11111/48682
dc.identifier.urnURN:NBN:fi-fe2023021627465
dc.language.isoen
dc.okm.affiliatedauthorSiekkinen, Reetta
dc.okm.affiliatedauthorHan, Chunlei
dc.okm.affiliatedauthorMaaniitty, Teemu
dc.okm.affiliatedauthorTeräs, Mika
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorSaraste, Antti
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1007/s12350-022-03164-5
dc.relation.ispartofjournalJournal of Nuclear Cardiology
dc.relation.volume30
dc.source.identifierhttps://www.utupub.fi/handle/10024/184670
dc.titleA retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
A retrospective evaluation of Bayesian-penalized likelihood reconstruction.pdf
Size:
2.73 MB
Format:
Adobe Portable Document Format