Quantification of porcine myocardial perfusion with modified dual bolus MRI-A prospective study with a PET reference

dc.contributor.authorMinna Husso
dc.contributor.authorMikko J. Nissi
dc.contributor.authorAntti Kuivanen
dc.contributor.authorPaavo Halonen
dc.contributor.authorMiikka Tarkia
dc.contributor.authorJarmo Teuho
dc.contributor.authorVirva Saunavaara
dc.contributor.authorPauli Vainio
dc.contributor.authorPetri Sipola
dc.contributor.authorHannu Manninen
dc.contributor.authorSeppo Ylä-Herttuala
dc.contributor.authorJuhani Knuuti
dc.contributor.authorJuha Töyräs
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organization-code2609810
dc.converis.publication-id42070622
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/42070622
dc.date.accessioned2022-10-28T14:22:17Z
dc.date.available2022-10-28T14:22:17Z
dc.description.abstract<div><h3>Background</h3><p>The reliable quantification of myocardial blood flow (<i>MBF</i>) with MRI, necessitates the correction of errors in arterial input function (AIF) caused by the T1 saturation effect. The aim of this study was to compare <i>MBF</i> determined by a traditional dual bolus method against a modified dual bolus approach and to evaluate both methods against PET in a porcine model of myocardial ischemia.</p><h3>Methods</h3><p>Local myocardial ischemia was induced in five pigs, which were subsequently examined with contrast enhanced MRI (gadoteric acid) and PET (O-15 water). In the determination of <i>MBF</i>, the initial high concentration AIF was corrected using the ratio of low and high contrast AIF areas, normalized according to the corresponding heart rates. <i>MBF</i> was determined from the MRI, during stress and at rest, using the dual bolus and the modified dual bolus methods in 24 segments of the myocardium (total of 240 segments, five pigs in stress and rest). Due to image artifacts and technical problems 53% of the segments had to be rejected from further analyses. These two estimates were later compared against respective rest and stress PET-based <i>MBF</i> measurements.</p><h3>Results</h3><p>Values of <i>MBF</i> were determined for 112/240 regions. Correlations for <i>MBF</i> between the modified dual bolus method and PET was <i>r</i><sub><i>s</i></sub> = 0.84, and between the traditional dual bolus method and PET <i>r</i><sub><i>s</i></sub> = 0.79. The intraclass correlation was very good (ICC = 0.85) between the modified dual bolus method and PET, but poor between the traditional dual bolus method and PET (ICC = 0.07).</p><h3>Conclusions</h3><p>The modified dual bolus method showed a better agreement with PET than the traditional dual bolus method. The modified dual bolus method was found to be more reliable than the traditional dual bolus method, especially when there was variation in the heart rate. However, the difference between the <i>MBF</i> values estimated with either of the two MRI-based dual-bolus methods and those estimated with the gold-standard PET method were statistically significant.</p></div>
dc.identifier.eissn1471-2342
dc.identifier.jour-issn1471-2342
dc.identifier.olddbid187868
dc.identifier.oldhandle10024/170962
dc.identifier.urihttps://www.utupub.fi/handle/11111/43331
dc.identifier.urnURN:NBN:fi-fe2021042826259
dc.language.isoen
dc.okm.affiliatedauthorTarkia, Miikka
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorSaunavaara, Virva
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline318 Medical biotechnologyen_GB
dc.okm.discipline318 Lääketieteen bioteknologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBioMed Central Ltd.
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumber58
dc.relation.doi10.1186/s12880-019-0359-8
dc.relation.ispartofjournalBMC Medical Imaging
dc.relation.issue1
dc.relation.volume19
dc.source.identifierhttps://www.utupub.fi/handle/10024/170962
dc.titleQuantification of porcine myocardial perfusion with modified dual bolus MRI-A prospective study with a PET reference
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s12880-019-0359-8.pdf
Size:
2.23 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version