Calibration of RADMON radiation monitor onboard Aalto-1 CubeSat
| dc.contributor.author | Oleynik P | |
| dc.contributor.author | Vainio R | |
| dc.contributor.author | Punkkinen A | |
| dc.contributor.author | Dudnik O | |
| dc.contributor.author | Gieseler J | |
| dc.contributor.author | Hedman H | |
| dc.contributor.author | Hietala H | |
| dc.contributor.author | Hæggström E | |
| dc.contributor.author | Niemelä P | |
| dc.contributor.author | Peltonen J | |
| dc.contributor.author | Praks J | |
| dc.contributor.author | Punkkinen R | |
| dc.contributor.author | Säntti T | |
| dc.contributor.author | Valtonen E | |
| dc.contributor.organization | fi=avaruustutkimuslaboratorio|en=Space Research Laboratory| | |
| dc.contributor.organization | fi=mikroelektroniikka|en=Microelectronics| | |
| dc.contributor.organization | fi=ohjelmistotekniikka|en=Software Engineering| | |
| dc.contributor.organization | fi=sulautettu elektroniikka|en=Embedded Electronics| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.47833719389 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.85550792098 | |
| dc.contributor.organization-code | 2606802 | |
| dc.contributor.organization-code | 2606804 | |
| dc.converis.publication-id | 45026066 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/45026066 | |
| dc.date.accessioned | 2022-10-27T11:56:15Z | |
| dc.date.available | 2022-10-27T11:56:15Z | |
| dc.description.abstract | RADMON is a small radiation monitor designed and assembled by students of University of Turku and University of Helsinki. It is flown on-board Aalto-1, a 3-unit CubeSat in low Earth orbit at about 500 km altitude. The detector unit of the instrument consists of two detectors, a Si solid-state detector and a CsI(Tl) scintillator, and utilizes the ΔE-E technique to determine the total energy and species of each particle hitting the detector. We present the results of the on-ground and in-flight calibration campaigns of the instrument, as well as the characterization of its response through extensive simulations within the Geant4 framework. The overall energy calibration margin achieved is about 5%. The full instrument response to protons and electrons is presented and the issue of proton contamination of the electron channels is quantified and discussed. | |
| dc.format.pagerange | 42 | |
| dc.format.pagerange | 51 | |
| dc.identifier.eissn | 1879-1948 | |
| dc.identifier.jour-issn | 0273-1177 | |
| dc.identifier.olddbid | 172931 | |
| dc.identifier.oldhandle | 10024/156025 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/30734 | |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0273117719308282 | |
| dc.identifier.urn | URN:NBN:fi-fe2021042612709 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Oleynik, Philipp | |
| dc.okm.affiliatedauthor | Vainio, Rami | |
| dc.okm.affiliatedauthor | Punkkinen, Arttu | |
| dc.okm.affiliatedauthor | Gieseler, Jan | |
| dc.okm.affiliatedauthor | Hedman, Hannu-Pekka | |
| dc.okm.affiliatedauthor | Hietala, Heli | |
| dc.okm.affiliatedauthor | Peltonen, Juhani | |
| dc.okm.affiliatedauthor | Punkkinen, Risto | |
| dc.okm.affiliatedauthor | Säntti, Tero | |
| dc.okm.affiliatedauthor | Valtonen, Eino | |
| dc.okm.discipline | 115 Astronomy and space science | en_GB |
| dc.okm.discipline | 115 Avaruustieteet ja tähtitiede | fi_FI |
| dc.okm.internationalcopublication | international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Elsevier Ltd | |
| dc.publisher.country | United Kingdom | en_GB |
| dc.publisher.country | Britannia | fi_FI |
| dc.publisher.country-code | GB | |
| dc.relation.doi | 10.1016/j.asr.2019.11.020 | |
| dc.relation.ispartofjournal | Advances in Space Research | |
| dc.relation.issue | 1 | |
| dc.relation.volume | 66 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/156025 | |
| dc.title | Calibration of RADMON radiation monitor onboard Aalto-1 CubeSat | |
| dc.year.issued | 2020 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Calibration of RADMON Radiation Monitor Onboard Aalto-1 CubeSat.pdf
- Size:
- 3.09 MB
- Format:
- Adobe Portable Document Format
- Description:
- Final draft