CLinical EValuation of WEB 17 device in intracranial aneuRysms (CLEVER): 1-year effectiveness results for ruptured and unruptured aneurysms

dc.contributor.authorSpelle, Laurent
dc.contributor.authorCostalat, Vincent
dc.contributor.authorCaroff, Jildaz
dc.contributor.authorWodarg, Fritz
dc.contributor.authorFischer, Sebastian
dc.contributor.authorHerbreteau, Denis
dc.contributor.authorMöhlenbruch, Markus A
dc.contributor.authorJanuel, Anne-Christine
dc.contributor.authorPapagiannaki, Chrysanthi
dc.contributor.authorKlisch, Joachim
dc.contributor.authorNumminen, Jussi
dc.contributor.authorRautio, Riitta
dc.contributor.authorBerlis, Ansgar
dc.contributor.authorMihalea, Cristian
dc.contributor.authorChalumeau, Vanessa
dc.contributor.authorDowner, Jonathan
dc.contributor.authorCortese, Jonathan
dc.contributor.authorIkka, Leon
dc.contributor.authorGallas, Sophie
dc.contributor.authorBester, Maxim
dc.contributor.authorLiebig, Thomas
dc.contributor.authorVelasco, Stéphane
dc.contributor.authorGrimaldi, Lamiae
dc.contributor.authorByrne, James
dc.contributor.authorSzikora, Istvan
dc.contributor.authorPierot, Laurent
dc.contributor.authorCognard, Christophe
dc.contributor.organizationfi=lääketieteellinen tiedekunta|en=Faculty of Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.13290506867
dc.converis.publication-id457219695
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/457219695
dc.date.accessioned2025-08-28T00:50:54Z
dc.date.available2025-08-28T00:50:54Z
dc.description.abstract<p><strong>Background: </strong>The Woven EndoBridge (WEB) device is designed to treat wide-necked bifurcation aneurysms. The WEB 17 is the latest iteration and can be delivered through a 0.017″ microcatheter. The CLEVER study demonstrated that WEB 17 is safe and effective for providing protection against bleeding or rebleeding at 1 month and 1 year.</p><p><strong>Objective: </strong>To evaluate angiographic stability at 1 year.</p><p><strong>Methods: </strong>The CLEVER study was a prospective multicenter study conducted in 17 European centers, involved 163 subjects, comprising 60 ruptured and 103 unruptured aneurysms. Independent assessment of 1-year follow-up imaging was incorporated into the study design.</p><p><strong>Results: </strong>Aneurysm diameters ranged from 2.0 to 9.2 mm, with 95.7% being broad-based (dome-to-neck ratio <2). Follow-up imaging at 1 year was completed for 146 out of 163 subjects (89.6%) and evaluated by an independent core laboratory. The primary efficacy endpoint of adequate occlusion without re-treatment at 1 year was achieved for 120 (82.2%) of all subjects. At 1 year, the adequate occlusion rate was 86.5% for ruptured aneurysms (73.1% complete occlusion) and 82.4% for unruptured aneurysms (57.1% complete occlusion). The overall re-treatment rate at 1 year was 2.6% (4/152), with 3.1% (3/97) for unruptured aneurysms and 1.8% (1/55) for ruptured aneurysms CONCLUSION: Delivery of the WEB 17 via 0.017 inch catheters represents a significant evolution of the WEB design. The results of CLEVER presented here demonstrate that it maintains the same efficacy as previous generations of WEB.</p>
dc.identifier.eissn1759-8486
dc.identifier.jour-issn1759-8478
dc.identifier.olddbid206531
dc.identifier.oldhandle10024/189558
dc.identifier.urihttps://www.utupub.fi/handle/11111/47079
dc.identifier.urlhttps://jnis.bmj.com/content/early/2024/07/10/jnis-2024-021918
dc.identifier.urnURN:NBN:fi-fe2025082787390
dc.language.isoen
dc.okm.affiliatedauthorRautio, Riitta
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3112 Neurosciencesen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3112 Neurotieteetfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBMJ Publishing Group
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1136/jnis-2024-021918
dc.relation.ispartofjournalJournal of NeuroInterventional Surgery
dc.source.identifierhttps://www.utupub.fi/handle/10024/189558
dc.titleCLinical EValuation of WEB 17 device in intracranial aneuRysms (CLEVER): 1-year effectiveness results for ruptured and unruptured aneurysms
dc.year.issued2024

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
jnis-2024-021918.full.pdf
Size:
745.25 KB
Format:
Adobe Portable Document Format