The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT

dc.contributor.authorShinya Akikazu
dc.contributor.authorIshida Yoshiki
dc.contributor.authorMiura Daisuke
dc.contributor.authorShinya Akiyoshi
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code2607500
dc.converis.publication-id68449641
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/68449641
dc.date.accessioned2022-10-28T14:26:51Z
dc.date.available2022-10-28T14:26:51Z
dc.description.abstractA three-dimensional (3D) finite element (FE) model of the mandibular bone was created from 3D X-ray CT scan images of a live human subject. Simulating the clinical situation of implant therapy at the mandibular first molar, virtual extraction of the tooth was performed at the 3D FE mandibular model, and 12 different implant diameters and lengths were virtually inserted in order to carry out a mechanical analysis. (1) High stress concentration was found at the surfaces of the buccal and lingual peri-implant bone adjacent to the sides of the neck in all the implants. (2) The greatest stress value was approximately 6.0 MPa with implant diameter of 3.8 mm, approx. 4.5 MPa with implant diameter of 4.3 mm, and approx. 3.2 MPa with implant diameter of 6.0 mm. (3) The stress on the peri-implant bone was found to decrease with increasing length and mainly in diameter of the implant.
dc.identifier.jour-issn1996-1944
dc.identifier.olddbid188318
dc.identifier.oldhandle10024/171412
dc.identifier.urihttps://www.utupub.fi/handle/11111/43644
dc.identifier.urnURN:NBN:fi-fe2022012711053
dc.language.isoen
dc.okm.affiliatedauthorShinya, Akikazu
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMDPI
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumberARTN 7344
dc.relation.doi10.3390/ma14237344
dc.relation.ispartofjournalMaterials
dc.relation.issue23
dc.relation.volume14
dc.source.identifierhttps://www.utupub.fi/handle/10024/171412
dc.titleThe Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
materials-14-07344-v2.pdf
Size:
2.92 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF