Benchmarking blood collection tubes and processing intervals for extracellular vesicle performance metrics

dc.contributor.authorDhondt Bert
dc.contributor.authorPinheiro Cláudio
dc.contributor.authorGeeurickx Edward
dc.contributor.authorTulkens Joeri
dc.contributor.authorVergauwen Glenn
dc.contributor.authorVan Der Pol Edwin
dc.contributor.authorNieuwland Rienk
dc.contributor.authorDecock Anneleen
dc.contributor.authorMiinalainen Ilkka
dc.contributor.authorRappu Pekka
dc.contributor.authorSchroth Gary
dc.contributor.authorKuersten Scott
dc.contributor.authorVandesompele Jo
dc.contributor.authorMestdagh Pieter
dc.contributor.authorLumen Nicolaas
dc.contributor.authorDe Wever Olivier
dc.contributor.authorHendrix An
dc.contributor.organizationfi=biokemia|en=Biochemistry|
dc.contributor.organization-code1.2.246.10.2458963.20.49728377729
dc.converis.publication-id179760315
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/179760315
dc.date.accessioned2025-08-28T02:58:17Z
dc.date.available2025-08-28T02:58:17Z
dc.description.abstractThe analysis of extracellular vesicles (EV) in blood samples is under intense investigation and holds the potential to deliver clinically meaningful biomarkers for health and disease. Technical variation must be minimized to confidently assess EV-associated biomarkers, but the impact of pre-analytics on EV characteristics in blood samples remains minimally explored. We present the results from the first large-scale EV Blood Benchmarking (EVBB) study in which we systematically compared 11 blood collection tubes (BCT; six preservation and five non-preservation) and three blood processing intervals (BPI; 1, 8 and 72 h) on defined performance metrics (n = 9). The EVBB study identifies a significant impact of multiple BCT and BPI on a diverse set of metrics reflecting blood sample quality, ex-vivo generation of blood-cell derived EV, EV recovery and EV-associated molecular signatures. The results assist the informed selection of the optimal BCT and BPI for EV analysis. The proposed metrics serve as a framework to guide future research on pre-analytics and further support methodological standardization of EV studies.
dc.identifier.eissn2001-3078
dc.identifier.jour-issn2001-3078
dc.identifier.olddbid210001
dc.identifier.oldhandle10024/193028
dc.identifier.urihttps://www.utupub.fi/handle/11111/50076
dc.identifier.urlhttps://doi.org/10.1002/jev2.12315
dc.identifier.urnURN:NBN:fi-fe2025082788528
dc.language.isoen
dc.okm.affiliatedauthorRappu, Pekka
dc.okm.discipline215 Chemical engineeringen_GB
dc.okm.discipline215 Teknillinen kemia, kemian prosessitekniikkafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherWiley
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumbere12315
dc.relation.doi10.1002/jev2.12315
dc.relation.ispartofjournalJournal of Extracellular Vesicles
dc.relation.issue5
dc.relation.volume12
dc.source.identifierhttps://www.utupub.fi/handle/10024/193028
dc.titleBenchmarking blood collection tubes and processing intervals for extracellular vesicle performance metrics
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
J of Extracellular Vesicle - 2023 - Dhondt - Benchmarking blood collection tubes and processing intervals for extracellular.pdf
Size:
4.48 MB
Format:
Adobe Portable Document Format