Assessing blood flow in uterine fibroids using intravoxel incoherent motion imaging compared with dynamic contrast-enhanced MRI

dc.contributor.authorSainio, Teija
dc.contributor.authorSaunavaara, Jani
dc.contributor.authorKomar, Gaber
dc.contributor.authorViitala, Antti
dc.contributor.authorOtonkoski, Saara
dc.contributor.authorJoronen, Kirsi
dc.contributor.authorPerheentupa, Antti
dc.contributor.authorSequeiros, Roberto Blanco
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=synnytys- ja naistentautioppi|en=Obstetrics and Gynaecology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.74725736230
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.converis.publication-id484787177
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/484787177
dc.date.accessioned2025-08-27T22:49:23Z
dc.date.available2025-08-27T22:49:23Z
dc.description.abstract<p>To assess the utility of IVIM parameters in evaluating uterine fibroid blood flow compared to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) derived blood flow. Sixteen premenopausal women with uterine fibroids were enrolled in this prospective study. Pelvic MRI scans were obtained for each subject, both with and without continuous intravenous infusion of oxytocin, known to decrease significantly uterine fibroid blood flow, to assess the changes in blood flow of uterine fibroids. IVIM and DCE analyses were conducted using separate dedicated software. The bi-exponential IVIM model was used to estimate perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). DCE blood flow values were derived via T1 perfusion deconvolution arithmetic, utilizing a first pass of an AIF curve. The correlation between the parameters were analyzed by Spearman's rank correlation analysis due to small sample size. Means of the parameters were compared with a nonparametric Wilcoxon sign rank method for each pair. Statistically significant positive correlations were found between perfusion fraction values and DCE blood flow values with oxytocin (Spearson's rho = 0.78, p = 0.0004), and between fD* values and DCE blood flow values with oxytocin (Spearson's rho = 0.64, p = 0.0071). Significant differences in blood flow were detected across most IVIM parameters: f, D*, and fD* (p < 0.001, p = 0.0027, and p = 0.0002, respectively) when comparing the values without oxytocin and with oxytocin. IVIM imaging shows promise for assessing blood flow in uterine fibroids.</p>
dc.identifier.jour-issn2045-2322
dc.identifier.olddbid202873
dc.identifier.oldhandle10024/185900
dc.identifier.urihttps://www.utupub.fi/handle/11111/50472
dc.identifier.urlhttps://www.nature.com/articles/s41598-024-83739-z
dc.identifier.urnURN:NBN:fi-fe2025082789929
dc.language.isoen
dc.okm.affiliatedauthorSainio, Teija
dc.okm.affiliatedauthorSaunavaara, Jani
dc.okm.affiliatedauthorKomar, Gaber
dc.okm.affiliatedauthorBlanco Sequeiros, Roberto
dc.okm.affiliatedauthorViitala, Antti
dc.okm.affiliatedauthorOtonkoski, Saara
dc.okm.affiliatedauthorJoronen, Kirsi
dc.okm.affiliatedauthorPerheentupa, Antti
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline318 Medical biotechnologyen_GB
dc.okm.discipline318 Lääketieteen bioteknologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherNATURE PORTFOLIO
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.publisher.placeBERLIN
dc.relation.articlenumber2980
dc.relation.doi10.1038/s41598-024-83739-z
dc.relation.ispartofjournalScientific Reports
dc.relation.issue1
dc.relation.volume15
dc.source.identifierhttps://www.utupub.fi/handle/10024/185900
dc.titleAssessing blood flow in uterine fibroids using intravoxel incoherent motion imaging compared with dynamic contrast-enhanced MRI
dc.year.issued2025

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s41598-024-83739-z.pdf
Size:
1.97 MB
Format:
Adobe Portable Document Format