Diagnostic efficacy and tolerability of molded plastic nasopharyngeal swab (FinSwab) compared to flocked nylon swab in detection of SARS-CoV-2 and other respiratory viruses

dc.contributor.authorLaine Miia
dc.contributor.authorAhti Jaakko
dc.contributor.authorPeltola Ville
dc.contributor.authorPeri Piritta
dc.contributor.authorHakanen Antti J.
dc.contributor.authorWaris Matti
dc.contributor.organizationfi=infektiotautioppi|en=Infectious Diseases|
dc.contributor.organization-code2607100
dc.converis.publication-id67967631
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/67967631
dc.date.accessioned2022-10-27T12:26:32Z
dc.date.available2022-10-27T12:26:32Z
dc.description.abstract<p>The supply of testing equipment is vital in controlling the spread of SARS-CoV-2. We compared the diagnostic efficacy and tolerability of molded plastic (FinSwab; Valukumpu, Finland) versus flocked nylon (FLOQSwab; Copan, Italy) nasopharyngeal swabs in a clinical setting. Adults (n = 112) with suspected symptomatic COVID-19 infection underwent nasopharyngeal sampling with FinSwab and FLOQSwab from the same nostril at a drive-in coronavirus testing station. In a subset of 36 patients the samples were collected in a randomized order to evaluate the discomfort associated with sampling. SARS-CoV-2 and 16 other respiratory viruses, as well as human β-actin mRNA were analyzed by using reverse transcriptase PCR (RT-PCR) assays. Among the 112 patients (mean age, 38 [standard deviation (SD), 14] years) β-actin mRNA was found in all samples. There was no difference in the β-actin mRNA cycle threshold (CT) values between FinSwab (mean, 22.3; SD, 3.61) and FLOQSwab (mean, 22.1; SD, 3.50; P = 0.46) swabs. There were 31 virus-positive cases (26 rhinovirus, 4 SARS-CoV-2, and 1 coronavirus-OC43), 24 of which were positive in both swabs; 3 rhinovirus positives were only found in the FinSwab, and similarly 4 rhinovirus positives were only found in the FLOQSwab. Rhinovirus CT values were similar between swab types. Of the 36 patients, 22 (61%) tolerated the sampling with the FinSwab better than with the FLOQSwab (P = 0.065). The molded plastic nasopharyngeal swab (FinSwab) was comparable to the standard flocked swab in terms of efficacy for respiratory virus detection and tolerability of sampling.<br>IMPORTANCE We demonstrate that a molded plastic swab is a valid alternative to conventional brush-like swabs in collection of a nasopharyngeal sample for virus diagnostics.<br></p>
dc.identifier.olddbid175519
dc.identifier.oldhandle10024/158613
dc.identifier.urihttps://www.utupub.fi/handle/11111/30827
dc.identifier.urlhttps://journals.asm.org/doi/10.1128/Spectrum.00736-21
dc.identifier.urnURN:NBN:fi-fe2021120859676
dc.language.isoen
dc.okm.affiliatedauthorLaine, Miia
dc.okm.affiliatedauthorAhti, Jaakko
dc.okm.affiliatedauthorPeltola, Ville
dc.okm.affiliatedauthorPeri, Piritta
dc.okm.affiliatedauthorHakanen, Antti
dc.okm.affiliatedauthorWaris, Matti
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherAmerican Society for Microbiology
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1128/Spectrum.00736-21
dc.relation.ispartofjournalMicrobiology spectrum
dc.relation.issue2
dc.relation.volume9
dc.source.identifierhttps://www.utupub.fi/handle/10024/158613
dc.titleDiagnostic efficacy and tolerability of molded plastic nasopharyngeal swab (FinSwab) compared to flocked nylon swab in detection of SARS-CoV-2 and other respiratory viruses
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Spectrum.00736-21.pdf
Size:
1.39 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF