Assessment of CAD-CAM polymers for digitally fabricated complete dentures

dc.contributor.authorPerea-Lowery L.
dc.contributor.authorMinja I.K.
dc.contributor.authorLassila L.
dc.contributor.authorRamakrishnaiah R.
dc.contributor.authorVallittu P.K.
dc.contributor.organizationfi=Turun kliininen biomateriaalikeskus (TCBC)|en=Turku Clinical Biomaterials Centre - TCBC |
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.15617843576
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id46139586
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/46139586
dc.date.accessioned2022-10-27T11:53:26Z
dc.date.available2022-10-27T11:53:26Z
dc.description.abstract<div><h3>Statement of problem</h3><p>Information on the mechanical properties of the materials used for manufacturing computer-engineered complete dentures is scarce.</p></div><div><h3>Purpose</h3><p>The purpose of this in vitro study was to evaluate the mechanical properties of 3 prepolymerized polymethyl methacrylate (PMMA) resins used in the fabrication of computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete dentures (CDs), as well as 2 denture base polymers used for conventionally fabricated CDs.</p></div><div><h3>Material and methods</h3><p>Three CAD-CAM materials were evaluated: Degos Dental L-Temp, IvoBase CAD, and Zirkonzahn Temp Basic Tissue. Two materials used for conventionally manufactured dentures were also included as controls (Palapress and Paladon 65). Each material type was sectioned into bars for flexural strength, nanohardness, elastic modulus, and surface microhardness evaluation (n=8/material). Half of the specimens were stored in water for 30 days, while the other half was dry-stored. A 2-way ANOVA was conducted to detect the effect of material and storage on the evaluated properties (α=.05). Linear contrasts were conducted to compare the differences among the 3 types of CAD-CAM material and the conventional ones.</p></div><div><h3>Results</h3><p>Material type and storage had a significant influence on the flexural strength, nanohardness, elastic modulus, and surface hardness of the materials investigated (<em>P</em><.001). The post hoc Scheffé test for flexural strength revealed a nonsignificant difference in the interaction between Degos L-Temp and Paladon (<em>P</em>=1.000). In terms of nanohardness, no difference was found when comparing Palapress with Paladon, as well as IvoBase CAD with Zirkonzahn Temp Basic (<em>P</em>=1.000). A nonsignificant interaction in terms of surface hardness was also found between IvoBase CAD and Palapress (<em>P</em>=.575).</p></div><div><h3>Conclusions</h3><p>The tested materials showed variation in their mechanical properties, with satisfactory behavior of the CAD-CAM materials. However, the results obtained when testing the materials used for the conventional fabrication of complete dentures suggest that their use might still be advisable.<br></p></div>
dc.format.pagerange175
dc.format.pagerange181
dc.identifier.eissn1097-6841
dc.identifier.jour-issn0022-3913
dc.identifier.olddbid172591
dc.identifier.oldhandle10024/155685
dc.identifier.urihttps://www.utupub.fi/handle/11111/30359
dc.identifier.urnURN:NBN:fi-fe2021042821754
dc.language.isoen
dc.okm.affiliatedauthorPerea, Leila
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMosby Inc.
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1016/j.prosdent.2019.12.008
dc.relation.ispartofjournalJournal of Prosthetic Dentistry
dc.relation.issue1
dc.relation.volume125
dc.source.identifierhttps://www.utupub.fi/handle/10024/155685
dc.titleAssessment of CAD-CAM polymers for digitally fabricated complete dentures
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
JPD-19-134 rev3 figs SR edits.pdf
Size:
991.48 KB
Format:
Adobe Portable Document Format
Description:
Final draft (Elsevier CC BY NC ND)