New opportunities for nuclear cardiology with total-body positron emission tomography/computed tomography

dc.contributor.authorSaraste, Antti
dc.contributor.authorKnuuti, Juhani
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=InFLAMES Lippulaiva|en=InFLAMES Flagship|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.68445910604
dc.converis.publication-id515628897
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/515628897
dc.date.accessioned2026-04-24T21:41:54Z
dc.description.abstractTotal-body positron emission tomography (PET) systems with a long axial field of view (LAFOV) are now commercially available and represent the state of the art in PET imaging. These systems provide wide anatomical coverage and markedly increased detection sensitivity. Clinical studies have demonstrated enhanced image quality, superior quantification, and benefits for tracer kinetic modeling through dynamic imaging. LAFOV PET/CT allows for substantial reductions in acquisition time and radiation dose while maintaining diagnostic image quality. Full-body coverage enables dynamic whole-body imaging, which enables tracer kinetic modeling across multiple organs and the large vascular structures, offering new opportunities for studying their interactions in cardiovascular and systemic diseases. Furthermore, these systems facilitate the development of new PET methods including pharmacokinetics of new tracers. This review discusses the emerging opportunities and challenges associated with the application of LAFOV PET/CT systems in cardiovascular diseases.
dc.identifier.eissn1532-6551
dc.identifier.jour-issn1071-3581
dc.identifier.urihttps://www.utupub.fi/handle/11111/59737
dc.identifier.urlhttps://doi.org/10.1016/j.nuclcard.2026.102652
dc.identifier.urnURN:NBN:fi-fe2026042333393
dc.language.isoen
dc.okm.affiliatedauthorSaraste, Antti
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA2 Scientific Article
dc.publisherElsevier BV
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumber102652
dc.relation.doi10.1016/j.nuclcard.2026.102652
dc.relation.ispartofjournalJournal of Nuclear Cardiology
dc.titleNew opportunities for nuclear cardiology with total-body positron emission tomography/computed tomography
dc.year.issued2026

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S1071358126000334-main.pdf
Size:
4.66 MB
Format:
Adobe Portable Document Format