Comparative color and surface parameters of current esthetic restorative CAD/CAM materials

dc.contributor.authorFerhan Egilmez
dc.contributor.authorGulfem Ergun
dc.contributor.authorIsil Cekic-Nagas
dc.contributor.authorPekka Kalevi Vallittu
dc.contributor.authorLippo Veli Juhana Lassila
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id31771770
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/31771770
dc.date.accessioned2022-10-28T13:16:41Z
dc.date.available2022-10-28T13:16:41Z
dc.description.abstract<p>PURPOSE. The purpose of this study was to derive and compare the inherent color (hue angle, chroma), translucency (TPSCI), surface gloss (Delta E*(SCE-SCI)), and surface roughness (R-a) amongst selected shades and brands of three hybrid CAD/CAM blocks [GC Cerasmart (CS); Lava Ultimate (LU); Vita Enamic (VE)].</p><p>MATERIALS AND METHODS. The specimens (N = 225) were prepared into square-shaped (12 x 12 mm(2)) with different thicknesses and shades. The measurements of color, translucency, and surface gloss were performed by a reflection spectrophotometer. The surface roughness and surface topography were assessed by white light interferometry. </p><p>RESULTS. Results revealed that hue and chroma values were influenced by the material type, material shade, and material thickness (P < .001). The order of hue angle amongst the materials was LU > CS > VE, whereas the order of chroma was VE > CS > LU. TPSCI results demonstrated a significant difference in terms of material types and material thicknesses (P <= .001). TPSCI values of the tested materials were ordered as LU > CS > VE. Delta E*(SCE-SCI) and R-a results were significantly varied amongst the materials (P < .001) and amongst the shades (P < .05). The order of Delta E*(SCE-SCI) amongst the materials were as follows LU > VE >= CS, whereas the order of R-a was CS >= VE > LU. CONCLUSION. Nano-ceramic and polymer-infiltrated-feldspathic ceramic-network CAD/CAM materials exhibited different optical, inherent color and surface parameters.</p>
dc.format.pagerange32
dc.format.pagerange42
dc.identifier.eissn2005-7814
dc.identifier.jour-issn2005-7806
dc.identifier.olddbid180981
dc.identifier.oldhandle10024/164075
dc.identifier.urihttps://www.utupub.fi/handle/11111/57956
dc.identifier.urnURN:NBN:fi-fe2021042719252
dc.language.isoen
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherKOREAN ACAD PROSTHODONTICS
dc.publisher.countryKorea, Republic of (South Korea)en_GB
dc.publisher.countryKorean tasavalta (Etelä-Korea)fi_FI
dc.publisher.country-codeKR
dc.relation.doi10.4047/jap.2018.10.1.32
dc.relation.ispartofjournalThe Journal of Advanced Prosthodontics
dc.relation.issue1
dc.relation.volume10
dc.source.identifierhttps://www.utupub.fi/handle/10024/164075
dc.titleComparative color and surface parameters of current esthetic restorative CAD/CAM materials
dc.year.issued2018

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
jap-10-32.pdf
Size:
682.33 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF