Development and clinical validation of a miniaturized finger probe for bedside hemodynamic monitoring

dc.contributor.authorPanula Tuukka
dc.contributor.authorSirkiä Jukka-Pekka
dc.contributor.authorKoivisto Tero
dc.contributor.authorPänkäälä Mikko
dc.contributor.authorNiiranen Teemu
dc.contributor.authorKantola Ilkka
dc.contributor.authorKaisti Matti
dc.contributor.organizationfi=lääketieteellinen tiedekunta|en=Faculty of Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organizationfi=tietotekniikan laitos|en=Department of Computing|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.13290506867
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.85312822902
dc.converis.publication-id181784765
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/181784765
dc.date.accessioned2025-08-28T02:11:42Z
dc.date.available2025-08-28T02:11:42Z
dc.description.abstractOur aim is to develop a blood pressure (BP) measurement technology that could be integrated into a finger-worn pulse oximeter, eliminating the need for a brachial cuff. We present a miniature cuffless tonometric finger probe system that uses the oscillometric method to measure BP. Our approach uses a motorized press that is used to apply pressure to the fingertip to measure BP. We verified the functionality of the device in a clinical trial (n = 43) resulting in systolic and diastolic pressures ((<i>mean</i> ± <i>SD</i>) mmHg) of (-3.5 ± 8.4) mmHg and (-4.0 ± 4.4) mmHg, respectively. Comparison was made with manual auscultation (n = 26) and automated cuff oscillometry (n = 18). In addition to BP, we demonstrated the ability of the device to assess arterial stiffness (n = 18) and detect atrial fibrillation (n = 6). We were able to introduce a sufficiently small device that could be used for convenient ambulatory measurements with minimal discomfort.
dc.identifier.eissn2589-0042
dc.identifier.olddbid208720
dc.identifier.oldhandle10024/191747
dc.identifier.urihttps://www.utupub.fi/handle/11111/58324
dc.identifier.urlhttps://doi.org/10.1016/j.isci.2023.108295
dc.identifier.urnURN:NBN:fi-fe2025082792101
dc.language.isoen
dc.okm.affiliatedauthorPanula, Tuukka
dc.okm.affiliatedauthorSirkiä, Jukka-Pekka
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.affiliatedauthorPänkäälä, Mikko
dc.okm.affiliatedauthorNiiranen, Teemu
dc.okm.affiliatedauthorKantola, Ilkka
dc.okm.affiliatedauthorKaisti, Matti
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline113 Computer and information sciencesen_GB
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline113 Tietojenkäsittely ja informaatiotieteetfi_FI
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherCell Press
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumber108295
dc.relation.doi10.1016/j.isci.2023.108295
dc.relation.ispartofjournaliScience
dc.relation.issue11
dc.relation.volume26
dc.source.identifierhttps://www.utupub.fi/handle/10024/191747
dc.titleDevelopment and clinical validation of a miniaturized finger probe for bedside hemodynamic monitoring
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S2589004223023726-main.pdf
Size:
3.57 MB
Format:
Adobe Portable Document Format