Evaluating Piezoelectric Ballistocardiography for Post-Surgical Heart Rate Monitoring

dc.contributor.authorSeifizarei, Sepehr
dc.contributor.authorElnaggar, Ismail
dc.contributor.authorRikken, Lars
dc.contributor.authorAnzanpour, Arman
dc.contributor.authorLinckens, Stephan
dc.contributor.authorToffoli, Enrico
dc.contributor.authorVandewauw, Ine
dc.contributor.authorVan De Poll
dc.contributor.authorMarcel CG
dc.contributor.authorAirola, Antti
dc.contributor.authorKaisti, Matti
dc.contributor.authorDe Kok, Margreet
dc.contributor.authorKoivisto, Tero
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.converis.publication-id477790500
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/477790500
dc.date.accessioned2025-08-28T00:01:56Z
dc.date.available2025-08-28T00:01:56Z
dc.description.abstract<p>Ballistocardiography (BCG) is a non-invasive technique measuring heart and circulatory activity, proposed as an alternative to ECG for long-term heart rate monitoring. This study evaluates a custom multi-node piezoelectric BCG sensing mat for heart rate measurement compared to single-lead ECG in post-cardiac surgery patients. 14 patients (10 males, mean age 63.47 ± 9.35) postcoronary artery bypass (N=8) or heart valve repair (N=6) were enrolled at Maastricht University Medical Center. Patients in the cardiac ICU used a bed with a custom BCG sensor mat (10 PVDF-TrFE piezoelectric sensors, 90x50 cm²). BCG and ECG were recorded simultaneously for an average of 15 hours per patient. BCG heart rate values were extracted over ten-second epochs using a multinode rule-based algorithm. Performance was assessed using mean absolute error (MAE) comparing BCG and ECG heart rates. Heart rate values derived from the piezoelectric BCG mat resulted in a weighted mean MAE of 1.41 bpm with 66.14% coverage compared to ECG. Piezoelectric BCG shows promise as an accurate heart rate measurement method in post-cardiac surgery patients, offering a non-invasive alternative to ECG. These findings support further development of this technology for clinical use in remote heart rate monitoring.</p>
dc.identifier.issn2325-8861
dc.identifier.jour-issn2325-8861
dc.identifier.olddbid205053
dc.identifier.oldhandle10024/188080
dc.identifier.urihttps://www.utupub.fi/handle/11111/53842
dc.identifier.urlhttps://doi.org/10.22489/cinc.2024.309
dc.identifier.urnURN:NBN:fi-fe2025082786879
dc.language.isoen
dc.okm.affiliatedauthorSeifizarei, Sepehr
dc.okm.affiliatedauthorElnaggar, Ismail
dc.okm.affiliatedauthorAnzanpour, Arman
dc.okm.affiliatedauthorAirola, Antti
dc.okm.affiliatedauthorKaisti, Matti
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.discipline113 Computer and information sciencesen_GB
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline113 Tietojenkäsittely ja informaatiotieteetfi_FI
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA4 Conference Article
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.conferenceComputing in cardiology conference
dc.relation.doi10.22489/cinc.2024.309
dc.relation.ispartofjournalComputing in Cardiology
dc.relation.volume51
dc.source.identifierhttps://www.utupub.fi/handle/10024/188080
dc.titleEvaluating Piezoelectric Ballistocardiography for Post-Surgical Heart Rate Monitoring
dc.title.bookComputing in Cardiology 2024
dc.year.issued2024

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
CinC2024-309.pdf
Size:
3.68 MB
Format:
Adobe Portable Document Format