Camera-Based Heart Rate Extraction in Noisy Environments

dc.contributor.authorRezaei, Amin
dc.contributor.departmentfi=Biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.facultyfi=Lääketieteellinen tiedekunta|en=Faculty of Medicine|
dc.contributor.studysubjectfi=Biomedical Imaging|en=Biomedical Imaging|
dc.date.accessioned2023-05-17T16:03:33Z
dc.date.available2023-05-17T16:03:33Z
dc.date.issued2023-03-02
dc.description.abstractRemote photoplethysmography (rPPG) is a non-invasive technique that benefits from video to measure vital signs such as the heart rate (HR). In rPPG estimation, noise can introduce artifacts that distort rPPG signal and jeopardize accurate HR measurement. Considering that most rPPG studies occurred in lab-controlled environments, the issue of noise in realistic conditions remains open. This thesis aims to examine the challenges of noise in rPPG estimation in realistic scenarios, specifically investigating the effect of noise arising from illumination variation and motion artifacts on the predicted rPPG HR. To mitigate the impact of noise, a modular rPPG measurement framework, comprising data preprocessing, region of interest, signal extraction, preparation, processing, and HR extraction is developed. The proposed pipeline is tested on the LGI-PPGI-Face-Video-Database public dataset, hosting four different candidates and real-life scenarios. In the RoI module, raw rPPG signals were extracted from the dataset using three machine learning-based face detectors, namely Haarcascade, Dlib, and MediaPipe, in parallel. Subsequently, the collected signals underwent preprocessing, independent component analysis, denoising, and frequency domain conversion for peak detection. Overall, the Dlib face detector leads to the most successful HR for the majority of scenarios. In 50% of all scenarios and candidates, the average predicted HR for Dlib is either in line or very close to the average reference HR. The extracted HRs from the Haarcascade and MediaPipe architectures make up 31.25% and 18.75% of plausible results, respectively. The analysis highlighted the importance of fixated facial landmarks in collecting quality raw data and reducing noise.
dc.format.extent111
dc.identifier.olddbid191692
dc.identifier.oldhandle10024/174776
dc.identifier.urihttps://www.utupub.fi/handle/11111/17973
dc.identifier.urnURN:NBN:fi-fe2023042037924
dc.language.isoeng
dc.rightsfi=Julkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.|en=This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.|
dc.rights.accessrightsavoin
dc.source.identifierhttps://www.utupub.fi/handle/10024/174776
dc.subjectRemote photoplethysmography, noise, heart rate, machine learning, independent component analysis, fast Fourier transform, facial landmarks.
dc.titleCamera-Based Heart Rate Extraction in Noisy Environments
dc.type.ontasotfi=Pro gradu -tutkielma|en=Master's thesis|

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Camera-Based Heart Rate Extraction in Noisy Environments.pdf
Size:
10.88 MB
Format:
Adobe Portable Document Format