15O-water PET perfusion in complex congenital heart disease

dc.contributor.authorKettunen, Sanna
dc.contributor.authorPaakkanen, Riitta
dc.contributor.authorOjala, Tiina
dc.contributor.authorMaaniitty, Teemu
dc.contributor.authorUusitalo, Valtteri
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.converis.publication-id516197532
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/516197532
dc.date.accessioned2026-04-24T16:51:34Z
dc.description.abstract<p>Aims</p><p>Positron emission tomography (PET) perfusion with <sup>15</sup>O-water is the reference standard for myocardial blood flow (MBF) quantification. Its strengths are low radiation dose, optimal tracer kinetics, and a short imaging protocol. However, the use of <sup>15</sup>O-water or PET perfusion in patients with various complex congenital heart diseases has been rarely studied. We report the initial experiences of <sup>15</sup>O-water PET perfusion in these patients.</p><p>Methods and results</p><p>All <sup>15</sup>O-water scans from patients with complex congenital heart disease at Helsinki University Hospital were retrospectively assessed (11/2021–11/2025). Thirteen congenital heart disease patients who underwent adenosine-stress <sup>15</sup>O-water PET were identified. Most common diagnoses were transposition of the great arteries (5/13, 38%), Tetralogy of Fallot (3/13, 23%), and univentricular heart (3/13, 23%). PET perfusion was diagnostic in all cases with no adverse effects reported. The radiation dose for stress protocol was 0.3 mSv for paediatric and 0.6 mSv for adult patients, and double when rest perfusion was also obtained to calculate myocardial flow reserve. The global stress MBF was normal (>2.3 mL/g/min) in 12/13 patients. Eleven patients (85%) had anatomical coronary imaging available, all without significant stenoses. One patient had an apical transmural scar on cardiac magnetic resonance imaging, and both stress and rest <sup>15</sup>O-water PET perfusion was decreased.</p><p>Conclusion</p><p><sup>15</sup>O-water PET offers a feasible and safe ultra-low-dose approach to quantify myocardial perfusion in complex congenital heart disease and may help identify flow-limiting disease when CT anatomy alone is inconclusive.</p>
dc.identifier.eissn2755-9637
dc.identifier.urihttps://www.utupub.fi/handle/11111/58856
dc.identifier.urlhttps://doi.org/10.1093/ehjimp/qyag033
dc.identifier.urnURN:NBN:fi-fe2026042332902
dc.language.isoen
dc.okm.affiliatedauthorMaaniitty, Teemu
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherOxford University Press (OUP)
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberqyag033
dc.relation.doi10.1093/ehjimp/qyag033
dc.relation.ispartofjournalEuropean heart journal : imaging methods and practice
dc.relation.issue3
dc.relation.volume3
dc.title15O-water PET perfusion in complex congenital heart disease
dc.year.issued2026

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
qyag033.pdf
Size:
499.86 KB
Format:
Adobe Portable Document Format