Glass Fiber Reinforced Composite Orthodontic Retainer: In Vitro Effect of Tooth Brushing on the Surface Wear and Mechanical Properties

dc.contributor.authorMaria Francesca Sfondrini
dc.contributor.authorPekka Kalevi Vallittu
dc.contributor.authorLippo Veli Juhana Lassila
dc.contributor.authorAnnalisa Viola
dc.contributor.authorPaola Gandini
dc.contributor.authorAndrea Scribante
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id46857847
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/46857847
dc.date.accessioned2022-10-28T14:40:38Z
dc.date.available2022-10-28T14:40:38Z
dc.description.abstractFiber reinforced composites (FRCs) are metal free materials that have many applications in dentistry. In clinical orthodontics, they are used as retainers after active treatment in order to avoid relapse. However, although the modulus of the elasticity of FRCs is low, the rigidity of the material in the form of a relatively thick retainer with a surface cover of a flowable resin composite is known to have higher structural rigidity than stainless steel splints. The aim of the present study is to measure load and bending stress of stainless steel wires, as well as flowable resin composite covered and spot-bonded FRC retainer materials after tooth brushing. These materials were tested with a three point bending test for three different conditions: no brushing, 26 min of brushing, and 60 min of brushing. SEM images were taken before and after different times of tooth brushing. Results showed that stainless steel was not significantly affected by tooth brushing. On the other hand, a significant reduction of values at maximum load at fracture was reported for both FRC groups, and uncovered FRCs were most affected. Concerning maximum bending stress, no significant reduction by pretreatment conditions was reported for the materials tested. SEM images showed no evident wear for stainless steel. Flowable resin composite covered FRCs showed some signs of composite wear, whereas spot-bonded FRCs, i.e., without the surface cover of a flowable resin composite, showed signs of wear on the FRC and exposed glass fibers from the FRC's polymer matrix. Because of the significant changes of the reduction of maximum load values and the wear for spot-bonded FRCs, this technique needs further in vitro and in vivo tests before it can be performed routinely in clinical practice.
dc.identifier.eissn1996-1944
dc.identifier.jour-issn1996-1944
dc.identifier.olddbid189624
dc.identifier.oldhandle10024/172718
dc.identifier.urihttps://www.utupub.fi/handle/11111/44698
dc.identifier.urlhttps://www.mdpi.com/1996-1944/13/5/1028
dc.identifier.urnURN:NBN:fi-fe2021042827526
dc.language.isoen
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.discipline216 Materials engineeringen_GB
dc.okm.discipline216 Materiaalitekniikkafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMDPI
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumberARTN 1028
dc.relation.doi10.3390/ma13051028
dc.relation.ispartofjournalMaterials
dc.relation.issue5
dc.relation.volume13
dc.source.identifierhttps://www.utupub.fi/handle/10024/172718
dc.titleGlass Fiber Reinforced Composite Orthodontic Retainer: In Vitro Effect of Tooth Brushing on the Surface Wear and Mechanical Properties
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
materials-13-01028-v2.pdf
Size:
3.68 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF