Indications and predictors for pacemaker implantation after isolated aortic valve replacement with bioprostheses: the CAREAVR study

dc.contributor.authorSalmi SJ
dc.contributor.authorNieminen T
dc.contributor.authorHartikainen J
dc.contributor.authorBiancari F
dc.contributor.authorLehto J
dc.contributor.authorNissinen M
dc.contributor.authorMalmberg M
dc.contributor.authorYannopoulos F
dc.contributor.authorSavolainen J
dc.contributor.authorAiraksinen J
dc.contributor.authorKiviniemi T
dc.contributor.organizationfi=kirurgia|en=Surgery|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code2607309
dc.converis.publication-id49583864
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/49583864
dc.date.accessioned2022-10-27T12:21:27Z
dc.date.available2022-10-27T12:21:27Z
dc.description.abstract<p><strong>Objectives: </strong>We sought to study the indications, long-term occurrence, and predictors of permanent pacemaker implantation (PPI) after isolated surgical aortic valve replacement with bioprostheses.</p><p><strong>Methods: </strong>The CAREAVR study included 704 patients (385 females, 54.7%) without a preoperative PPI (mean ± standard deviation age 75 ± 7 years) undergoing isolated surgical aortic valve replacement at 4 Finnish hospitals between 2002 and 2014. Data were extracted from electronic patient records.</p><p><strong>Results: </strong>The follow-up was median 4.7 years (range 1 day to 12.3 years). Altogether 56 patients received PPI postoperatively, with the median 507 days from the operation (range 6 days to 10.0 years). The PPI indications were atrioventricular block (31 patients, 55%) and sick sinus syndrome (21 patients, 37.5%). For 4 patients, the PPI indication remained unknown. A competing risks regression analysis (Fine-Gray method), adjusted with age, sex, diabetes, coronary artery disease, preoperative atrial fibrillation (AF), left ventricular ejection fraction, New York Heart Association class, AF at discharge and urgency of operation, was used to assess risk factors for PPI. Only AF at discharge (subdistribution hazard ratio 4.34, 95% confidence interval 2.34-8.03) was a predictor for a PPI.</p><p><strong>Conclusions: </strong>Though atrioventricular block is the major indication for PPI after surgical aortic valve replacement, >30% of PPIs are implanted due to sick sinus syndrome during both short-term follow-up and long-term follow-up. Postoperative AF versus sinus rhythm conveys >4-fold risk of PPI.</p>
dc.format.pagerange398
dc.format.pagerange404
dc.identifier.eissn1569-9285
dc.identifier.jour-issn1569-9293
dc.identifier.olddbid174953
dc.identifier.oldhandle10024/158047
dc.identifier.urihttps://www.utupub.fi/handle/11111/35118
dc.identifier.urnURN:NBN:fi-fe2021042823351
dc.language.isoen
dc.okm.affiliatedauthorBiancari, Fausto
dc.okm.affiliatedauthorLehto, Joonas
dc.okm.affiliatedauthorMalmberg, Markus
dc.okm.affiliatedauthorAiraksinen, Juhani
dc.okm.affiliatedauthorKiviniemi, Tuomas
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1093/icvts/ivaa119
dc.relation.ispartofjournalInteractive Cardiovascular and Thoracic Surgery
dc.relation.issue3
dc.relation.volume31
dc.source.identifierhttps://www.utupub.fi/handle/10024/158047
dc.titleIndications and predictors for pacemaker implantation after isolated aortic valve replacement with bioprostheses: the CAREAVR study
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Final_utucris.pdf
Size:
904.68 KB
Format:
Adobe Portable Document Format
Description:
Final draft