Guidelines for reporting methods to estimate metabolic rates by aquatic intermittent-flow respirometry

dc.contributor.authorKillen Shaun S.
dc.contributor.authorChristensen Emil AF
dc.contributor.authorCortese Daphne
dc.contributor.authorZávorka Libor
dc.contributor.authorNorin Tommy
dc.contributor.authorCotgrove Lucy
dc.contributor.authorCrespel Amélie
dc.contributor.authorMunson Amelia
dc.contributor.authorNati Julie JH
dc.contributor.authorPapatheodoulou Magdalene
dc.contributor.authorMcKenzie David J
dc.contributor.organizationfi=fysiologia ja genetiikka|en=Physiology and Genetics|
dc.contributor.organization-code1.2.246.10.2458963.20.70712835001
dc.converis.publication-id67547037
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/67547037
dc.date.accessioned2022-10-28T12:46:15Z
dc.date.available2022-10-28T12:46:15Z
dc.description.abstractInterest in the measurement of metabolic rates is growing rapidly, because of the importance of metabolism in advancing our understanding of organismal physiology, behaviour, evolution and responses to environmental change. The study of metabolism in aquatic animals is undergoing an especially pronounced expansion, with more researchers utilising intermittent-flow respirometry as a research tool than ever before. Aquatic respirometry measures the rate of oxygen uptake as a proxy for metabolic rate, and the intermittent-flow technique has numerous strengths for use with aquatic animals, allowing metabolic rate to be repeatedly estimated on individual animals over several hours or days and during exposure to various conditions or stimuli. There are, however, no published guidelines for the reporting of methodological details when using this method. Here, we provide the first guidelines for reporting intermittent-flow respirometry methods, in the form of a checklist of criteria that we consider to be the minimum required for the interpretation, evaluation and replication of experiments using intermittent-flow respirometry. Furthermore, using a survey of the existing literature, we show that there has been incomplete and inconsistent reporting of methods for intermittent-flow respirometry over the past few decades. Use of the provided checklist of required criteria by researchers when publishing their work should increase consistency of the reporting of methods for studies that use intermittent-flow respirometry. With the steep increase in studies using intermittent-flow respirometry, now is the ideal time to standardise reporting of methods, so that - in the future - data can be properly assessed by other scientists and conservationists.
dc.identifier.jour-issn0022-0949
dc.identifier.olddbid178840
dc.identifier.oldhandle10024/161934
dc.identifier.urihttps://www.utupub.fi/handle/11111/36439
dc.identifier.urnURN:NBN:fi-fe2021120158413
dc.language.isoen
dc.okm.affiliatedauthorCrespel, Amélie
dc.okm.discipline1184 Genetics, developmental biology, physiologyen_GB
dc.okm.discipline1184 Genetiikka, kehitysbiologia, fysiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeB1 Scientific Journal
dc.publisherCOMPANY BIOLOGISTS LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberARTN jeb242522
dc.relation.doi10.1242/jeb.242522
dc.relation.ispartofjournalJournal of Experimental Biology
dc.relation.issue18
dc.relation.volume224
dc.source.identifierhttps://www.utupub.fi/handle/10024/161934
dc.titleGuidelines for reporting methods to estimate metabolic rates by aquatic intermittent-flow respirometry
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
jeb242522.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF