Implant Survival of Constrained Acetabular Device in Primary Total Hip Arthroplasty Based on Data From the Finnish Arthroplasty Register

dc.contributor.authorMikko Karvonen
dc.contributor.authorInari Laaksonen
dc.contributor.authorPekka Pulkkinen
dc.contributor.authorAntti Eskelinen
dc.contributor.authorJaason Haapakoski
dc.contributor.authorAri-Pekka Puhto
dc.contributor.authorJukka Kettunen
dc.contributor.authorMikko Manninen
dc.contributor.authorKeijo T. Mäkelä
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607310
dc.converis.publication-id44234913
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/44234913
dc.date.accessioned2022-10-28T14:31:28Z
dc.date.available2022-10-28T14:31:28Z
dc.description.abstractBackground: Constrained acetabular devices were developed to prevent dislocations after total hip arthroplasty (THA). However, the data on their success have been contradictory. In this study, we aimed to assess implant survival of the constrained acetabular device in primary THA based on the Finnish Arthroplasty Register data.Methods: A total of 373 primary THAs with constrained acetabular devices inserted from 2006 to 2017 were included. A reference group was formed on a 1:3 basis and matched for age, sex, and diagnosis, consisting of 1118 conventional THAs. Implant survival estimates using death as a competing risk were assessed with revision for any reason and for any aseptic reason as the endpoints. The Cox multiple regression models were adjusted for age, sex, and diagnosis. The mean follow-up time was 3.3 (0-12.4) years for the constrained device group and 3.8 (0-12.0) years for the reference group.Results: Overall, there were 21 revisions in the constrained device group and 49 in the reference group. The 8-year survivorship for any reason was 94% (confidence interval [CI]: 91-96) for the constrained device group and 93% (CI: 89-97) for the reference group. With revision for any aseptic reason as the endpoint, the 8-year survivorships were 97% (CI: 95-99) and 94% (CI: 90-98), respectively. During the first 1.5 years, the constrained acetabular device group had a similar revision risk (hazard ratio: 1.09 [CI: 0.57-2.07], P = .8) to that of the reference group.Conclusion: The constrained acetabular device had good survival in primary THA, and our results support its continued use even in high-risk patients.
dc.format.pagerange219
dc.format.pagerange223
dc.identifier.eissn1532-8406
dc.identifier.jour-issn0883-5403
dc.identifier.olddbid188770
dc.identifier.oldhandle10024/171864
dc.identifier.urihttps://www.utupub.fi/handle/11111/55787
dc.identifier.urnURN:NBN:fi-fe2021042826933
dc.language.isoen
dc.okm.affiliatedauthorKarvonen, Mikko
dc.okm.affiliatedauthorLaaksonen, Inari
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1016/j.arth.2019.08.027
dc.relation.ispartofjournalJournal of Arthroplasty
dc.relation.issue1
dc.relation.volume35
dc.source.identifierhttps://www.utupub.fi/handle/10024/171864
dc.titleImplant Survival of Constrained Acetabular Device in Primary Total Hip Arthroplasty Based on Data From the Finnish Arthroplasty Register
dc.year.issued2020