A 15-min non-competitive homogeneous assay for microcystin and nodularin based on time-resolved Förster resonance energy transfer (TR-FRET)
| dc.contributor.author | Akter Sultana | |
| dc.contributor.author | Lamminmäki Urpo | |
| dc.contributor.organization | fi=biotekniikka|en=Biotechnology| | |
| dc.contributor.organization | fi=bioteknologian laitos|en=Department of Life Technologies| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.66532595361 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.98373201676 | |
| dc.converis.publication-id | 57561615 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/57561615 | |
| dc.date.accessioned | 2022-10-28T13:39:50Z | |
| dc.date.available | 2022-10-28T13:39:50Z | |
| dc.description.abstract | <p>Simple and rapid methods are required for screening and analysis of water samples to detect cyanobacterial cyclic peptide hepatotoxins: microcystin/nodularin. Previously, we reported a highly sensitive non-competitive heterogeneous assay for microcystin/nodularin utilizing a generic anti-immunocomplex (anti-IC) single-chain fragment of antibody variable domains (scFv) isolated from a synthetic antibody library together with a generic adda ((2S,3S,4E,6E,8S,9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4,6-dienoic acid)-specific monoclonal antibody (Mab) recognizing the common adda part of the microcystin/nodularin. Using the same antibody pair, here we report a homogeneous non-competitive assay for microcystin/nodularin based on TR-FRET (time-resolved Förster resonance energy transfer) measurement. The anti-IC scFv labeled with Alexa Fluor 680 and the Mab labeled with europium enabled the FRET process to occur in the presence of microcystin/nodularin. The TR-FRET signal is proportional to the toxin concentration in the sample. The rapid (15 min) homogeneous assay without requiring any washing step detected all the tested nine toxin variants (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF -LW, and nodularin-R). Very good signal to blank ratio (~13) was achieved using microcystin-LR and the sample detection limit (blank+3SD of blank) for microcystin-LR was ~0.3 μg/L (~0.08 μg/L in 80-μL reaction well). The practical application of the TR-FRET assay was demonstrated with water samples spiked with microcystin-LR as well as with environmental water. The average recoveries of microcystin-LR from spiked water ranged from 65 to 123%. Good correlation (<i>r</i><sup>2</sup> = 0.73 to 0.99) with other methods (liquid chromatography-mass spectrometry and previously reported heterogeneous assay) was found when environmental samples were analyzed. The developed wash-free assay has the potential to play as a quick screening tool to detect microcystin/nodularin from water below the World Health Organization’s guideline limit (1 μg/L of microcystin-LR).</p> | |
| dc.format.pagerange | 6170 | |
| dc.identifier.eissn | 1618-2650 | |
| dc.identifier.jour-issn | 1618-2642 | |
| dc.identifier.olddbid | 183458 | |
| dc.identifier.oldhandle | 10024/166552 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/40740 | |
| dc.identifier.url | https://doi.org/10.1007/s00216-021-03375-8 | |
| dc.identifier.urn | URN:NBN:fi-fe2021093048724 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Akter, Sultana | |
| dc.okm.affiliatedauthor | Lamminmäki, Urpo | |
| dc.okm.discipline | 219 Environmental biotechnology | en_GB |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Springer | |
| dc.publisher.country | Germany | en_GB |
| dc.publisher.country | Saksa | fi_FI |
| dc.publisher.country-code | DE | |
| dc.relation.doi | 10.1007/s00216-021-03375-8 | |
| dc.relation.ispartofjournal | Analytical and Bioanalytical Chemistry | |
| dc.relation.volume | 413 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/166552 | |
| dc.title | A 15-min non-competitive homogeneous assay for microcystin and nodularin based on time-resolved Förster resonance energy transfer (TR-FRET) | |
| dc.year.issued | 2021 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Akter-Lamminmäki2021_Article_A15-minNon-competitiveHomogene.pdf
- Size:
- 635.07 KB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's PDF