A 15-min non-competitive homogeneous assay for microcystin and nodularin based on time-resolved Förster resonance energy transfer (TR-FRET)

dc.contributor.authorAkter Sultana
dc.contributor.authorLamminmäki Urpo
dc.contributor.organizationfi=biotekniikka|en=Biotechnology|
dc.contributor.organizationfi=bioteknologian laitos|en=Department of Life Technologies|
dc.contributor.organization-code1.2.246.10.2458963.20.66532595361
dc.contributor.organization-code1.2.246.10.2458963.20.98373201676
dc.converis.publication-id57561615
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/57561615
dc.date.accessioned2022-10-28T13:39:50Z
dc.date.available2022-10-28T13:39:50Z
dc.description.abstract<p>Simple and rapid methods are required for screening and analysis of water samples to detect cyanobacterial cyclic peptide hepatotoxins: microcystin/nodularin. Previously, we reported a highly sensitive non-competitive heterogeneous assay for microcystin/nodularin utilizing a generic anti-immunocomplex (anti-IC) single-chain fragment of antibody variable domains (scFv) isolated from a synthetic antibody library together with a generic adda ((2S,3S,4E,6E,8S,9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4,6-dienoic acid)-specific monoclonal antibody (Mab) recognizing the common adda part of the microcystin/nodularin. Using the same antibody pair, here we report a homogeneous non-competitive assay for microcystin/nodularin based on TR-FRET (time-resolved Förster resonance energy transfer) measurement. The anti-IC scFv labeled with Alexa Fluor 680 and the Mab labeled with europium enabled the FRET process to occur in the presence of microcystin/nodularin. The TR-FRET signal is proportional to the toxin concentration in the sample. The rapid (15 min) homogeneous assay without requiring any washing step detected all the tested nine toxin variants (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF -LW, and nodularin-R). Very good signal to blank ratio (~13) was achieved using microcystin-LR and the sample detection limit (blank+3SD of blank) for microcystin-LR was ~0.3 μg/L (~0.08 μg/L in 80-μL reaction well). The practical application of the TR-FRET assay was demonstrated with water samples spiked with microcystin-LR as well as with environmental water. The average recoveries of microcystin-LR from spiked water ranged from 65 to 123%. Good correlation (<i>r</i><sup>2</sup> = 0.73 to 0.99) with other methods (liquid chromatography-mass spectrometry and previously reported heterogeneous assay) was found when environmental samples were analyzed. The developed wash-free assay has the potential to play as a quick screening tool to detect microcystin/nodularin from water below the World Health Organization’s guideline limit (1 μg/L of microcystin-LR).</p>
dc.format.pagerange6170
dc.identifier.eissn1618-2650
dc.identifier.jour-issn1618-2642
dc.identifier.olddbid183458
dc.identifier.oldhandle10024/166552
dc.identifier.urihttps://www.utupub.fi/handle/11111/40740
dc.identifier.urlhttps://doi.org/10.1007/s00216-021-03375-8
dc.identifier.urnURN:NBN:fi-fe2021093048724
dc.language.isoen
dc.okm.affiliatedauthorAkter, Sultana
dc.okm.affiliatedauthorLamminmäki, Urpo
dc.okm.discipline219 Environmental biotechnologyen_GB
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer
dc.publisher.countryGermanyen_GB
dc.publisher.countrySaksafi_FI
dc.publisher.country-codeDE
dc.relation.doi10.1007/s00216-021-03375-8
dc.relation.ispartofjournalAnalytical and Bioanalytical Chemistry
dc.relation.volume413
dc.source.identifierhttps://www.utupub.fi/handle/10024/166552
dc.titleA 15-min non-competitive homogeneous assay for microcystin and nodularin based on time-resolved Förster resonance energy transfer (TR-FRET)
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Akter-Lamminmäki2021_Article_A15-minNon-competitiveHomogene.pdf
Size:
635.07 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF