Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League

dc.contributor.authorStergiou, George S.
dc.contributor.authorKyriakoulis, Konstantinos G.
dc.contributor.authorKollias, Anastasios
dc.contributor.authorMcmanus, Richard J.
dc.contributor.authorMenti, Ariadni
dc.contributor.authorParati, Gianfranco
dc.contributor.authorSchutte, Aletta E.
dc.contributor.authorWang, Jiguang
dc.contributor.authorAsayama, Kei
dc.contributor.authorAsmar, Roland
dc.contributor.authorBilo, Grzegorz
dc.contributor.authorChapman, Niamh
dc.contributor.authorFujiwara, Takeshi
dc.contributor.authorHead, Geoffrey
dc.contributor.authorKahn, Nadia
dc.contributor.authorKario, Kazuomi
dc.contributor.authorLi, Yan
dc.contributor.authorManios, Efstathios
dc.contributor.authorMariglis, Dimitrios
dc.contributor.authorMihailidou, Anastasia S.
dc.contributor.authorMuntner, Paul
dc.contributor.authorMyers, Martin
dc.contributor.authorNiiranen, Teemu
dc.contributor.authorOhkubo, Takayoshi
dc.contributor.authorOmboni, Stefano
dc.contributor.authorProtogerou, Athanasios
dc.contributor.authorSaladini, Francesca
dc.contributor.authorSharman, James
dc.contributor.authorShimbo, Daichi
dc.contributor.authorde la Sierra
dc.contributor.authorAlejandro
dc.contributor.authorPalatini, Paolo
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.converis.publication-id491352655
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/491352655
dc.date.accessioned2026-04-24T20:09:46Z
dc.description.abstractKiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.
dc.embargo.lift2026-04-30
dc.format.pagerange588
dc.format.pagerange577
dc.identifier.eissn1473-5598
dc.identifier.jour-issn0263-6352
dc.identifier.urihttps://www.utupub.fi/handle/11111/59435
dc.identifier.urlhttps://doi.org/10.1097/hjh.0000000000003965
dc.identifier.urnURN:NBN:fi-fe2026042333215
dc.language.isoen
dc.okm.affiliatedauthorNiiranen, Teemu
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA2 Scientific Article
dc.publisherOvid Technologies (Wolters Kluwer Health)
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.publisher.placePHILADELPHIA
dc.relation.doi10.1097/HJH.0000000000003965
dc.relation.ispartofjournalJournal of Hypertension
dc.relation.issue4
dc.relation.volume43
dc.titleBlood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League
dc.year.issued2025

Tiedostot