Automated SPECT analysis compared with expert visual scoring for the detection of FFR-defined coronary artery disease

dc.contributor.authorR. S. Driessen
dc.contributor.authorP. G. Raijmakers
dc.contributor.authorI. Danad
dc.contributor.authorW. J. Stuijfzand
dc.contributor.authorS. P. Schumacher
dc.contributor.authorJ.A. Leipsic
dc.contributor.authorJ. K. Min
dc.contributor.authorJ. Knuuti
dc.contributor.authorA. A. Lammertsma
dc.contributor.authorA. C. van Rossum
dc.contributor.authorN. van Royen
dc.contributor.authorS. R. Underwood
dc.contributor.authorP. Knaapen
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.converis.publication-id30431341
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/30431341
dc.date.accessioned2025-08-27T23:19:19Z
dc.date.available2025-08-27T23:19:19Z
dc.description.abstract<div><h3>Purpose<br />Traditionally, interpretation of myocardial perfusion imaging (MPI) is based on visual assessment. Computer-based automated analysis might be a simple alternative obviating the need for extensive reading experience. Therefore, the aim of the present study was to compare the diagnostic performance of automated analysis with that of expert visual reading for the detection of obstructive coronary artery disease (CAD).<br />Methods<br />206 Patients (64% men, age 58.2 ± 8.7 years) with suspected CAD were included prospectively. All patients underwent 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) and invasive coronary angiography with fractional flow reserve (FFR) measurements. Non-corrected (NC) and attenuation-corrected (AC) SPECT images were analyzed both visually as well as automatically by commercially available SPECT software. Automated analysis comprised a segmental summed stress score (SSS), summed difference score (SDS), stress total perfusion deficit (S-TPD), and ischemic total perfusion deficit (I-TPD), representing the extent and severity of hypoperfused myocardium. Subsequently, software was optimized with an institutional normal database and thresholds. Diagnostic performances of automated and visual analysis were compared taking FFR as a reference.<br />Results<br />Sensitivity did not differ significantly between visual reading and most automated scoring parameters, except for SDS, which was significantly higher than visual assessment (p < 0.001). Specificity, however, was significantly higher for visual reading than for any of the automated scores (p < 0.001 for all). Diagnostic accuracy was significantly higher for visual scoring (77.2%) than for all NC images scores (p < 0.05), but not compared with SSS AC and S-TPD AC (69.8% and 71.2%, p = 0.063 and p = 0.134). After optimization of the automated software, diagnostic accuracies were similar for visual (73.8%) and automated analysis. Among the automated parameters, S-TPD AC showed the highest accuracy (73.5%).<br />Conclusion<br />Automated analysis of myocardial perfusion SPECT can be as accurate as visual interpretation by an expert reader in detecting significant CAD defined by FFR.<br /></h3></div>
dc.format.pagerange1100
dc.identifier.eissn1619-7089
dc.identifier.jour-issn1619-7070
dc.identifier.olddbid203800
dc.identifier.oldhandle10024/186827
dc.identifier.urihttps://www.utupub.fi/handle/11111/49333
dc.identifier.urnURN:NBN:fi-fe2021042718944
dc.language.isoen
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer Berlin Heidelberg
dc.publisher.countryGermanyen_GB
dc.publisher.countrySaksafi_FI
dc.publisher.country-codeDE
dc.relation.doi10.1007/s00259-018-3951-1
dc.relation.ispartofjournalEuropean Journal of Nuclear Medicine and Molecular Imaging
dc.relation.issue7
dc.relation.volume45
dc.source.identifierhttps://www.utupub.fi/handle/10024/186827
dc.titleAutomated SPECT analysis compared with expert visual scoring for the detection of FFR-defined coronary artery disease
dc.year.issued2018

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
10.1007_s00259-018-3951-1.pdf
Size:
4.89 MB
Format:
Adobe Portable Document Format
Description:
Publisher´s PDF