Diagnostic performance of short noncontrast biparametric 3-T MRI for tonsillar infections: comparison with a full protocol including contrast-enhanced sequences

dc.contributor.authorVierula Jari-Pekka
dc.contributor.authorNurminen Janne
dc.contributor.authorJussila Ville
dc.contributor.authorNyman Mikko
dc.contributor.authorHeikkinen Jaakko
dc.contributor.authorPape Bernd
dc.contributor.authorSorvettula Kaarlo
dc.contributor.authorMattila Kimmo
dc.contributor.authorHirvonen Jussi
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.contributor.organization-code2607303
dc.converis.publication-id181905237
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/181905237
dc.date.accessioned2025-08-28T01:04:24Z
dc.date.available2025-08-28T01:04:24Z
dc.description.abstract<p>Background<br>We investigated whether a short, 5-min magnetic resonance imaging (MRI) protocol consisting of only axial T2-weighted and diffusion-weighted imaging (DWI) sequences can discriminate between tonsillar infections, peritonsillar abscesses and deeply extending abscesses in a retrospective, blinded, multireader setting.</p><p>Methods<br>We included patients sent by emergency physicians with suspected pharyngotonsillar infections who underwent emergency neck 3-T MRI from April 1 2013 to December 31 2018. Three radiologists (with 10−16 years of experience) reviewed the images for abscesses and their extension into deep neck spaces. Data were reviewed first using only axial T2-weighted Dixon images and DWI (short protocol) and second including other sequences and contrast-enhanced T1-weighted Dixon images (full protocol). Diagnostic accuracy, interobserver agreement, and reader confidence were measured. Surgical findings and clinical course served as standard of reference.</p><p>Results<br>The final sample consisted of 52 patients: 13 acute tonsillitis with no abscesses, 19 peritonsillar abscesses, and 20 deeply extending abscesses. Using the short protocol, diagnostic accuracy for abscesses across all readers was good-to-excellent: sensitivity 0.93 (95% confidence interval 0.87−0.97), specificity 0.85 (0.70−0.93), accuracy 0.91 (0.85−0.95). Using the full protocol, respective values were 0.98 (0.93−1.00), 0.85 (0.70−0.93), and 0.95 (0.90−0.97), not significantly different compared with the short protocol. Similar trends were seen with detecting deep extension. Interobserver agreement was similar between protocols. However, readers had higher confidence in diagnosing abscesses using the full protocol.</p><p>Conclusions<br>Short MRI protocol showed good-to-excellent accuracy for tonsillar abscesses. Contrast-enhanced images improved reader confidence but did not affect diagnostic accuracy or interobserver agreement.<br></p>
dc.identifier.eissn2509-9280
dc.identifier.olddbid206966
dc.identifier.oldhandle10024/189993
dc.identifier.urihttps://www.utupub.fi/handle/11111/49558
dc.identifier.urlhttps://eurradiolexp.springeropen.com/articles/10.1186/s41747-023-00379-0
dc.identifier.urnURN:NBN:fi-fe2025082791449
dc.language.isoen
dc.okm.affiliatedauthorVierula, Jari-Pekka
dc.okm.affiliatedauthorNurminen, Janne
dc.okm.affiliatedauthorJussila, Ville
dc.okm.affiliatedauthorNyman, Mikko
dc.okm.affiliatedauthorHeikkinen, Jaakko
dc.okm.affiliatedauthorPape, Bernd
dc.okm.affiliatedauthorMattila, Kimmo
dc.okm.affiliatedauthorHirvonen, Jussi
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumber65
dc.relation.doi10.1186/s41747-023-00379-0
dc.relation.ispartofjournalEuropean radiology experimental
dc.relation.issue1
dc.relation.volume7
dc.source.identifierhttps://www.utupub.fi/handle/10024/189993
dc.titleDiagnostic performance of short noncontrast biparametric 3-T MRI for tonsillar infections: comparison with a full protocol including contrast-enhanced sequences
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s41747-023-00379-0.pdf
Size:
1.97 MB
Format:
Adobe Portable Document Format