Long cardiac troponin T forms in a healthy reference population

dc.contributor.authorTuominen, Tuulia
dc.contributor.authorVasankari, Tuija
dc.contributor.authorJunes, Helea
dc.contributor.authorSalonen, Selma
dc.contributor.authorTeppo, Konsta
dc.contributor.authorLinko-Parvinen, Anna
dc.contributor.authorPallari, Hanna-Mari
dc.contributor.authorAiraksinen, K.E. Juhani
dc.contributor.authorWittfooth, Saara
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organization-code1.2.246.10.2458963.20.98373201676
dc.converis.publication-id498749199
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/498749199
dc.date.accessioned2025-08-27T23:05:07Z
dc.date.available2025-08-27T23:05:07Z
dc.description.abstract<p><strong>Background</strong></p><p>Cardiac troponin T (cTnT) is an established biomarker in the diagnosis of myocardial infarction (MI). Recent studies show better discrimination between MI and other conditions when measuring only intact or minimally fragmented cTnT forms (long cTnT), compared to current cTnT assays that measure both intact and highly fragmented cTnT forms (total cTnT). This study investigated the long cTnT concentrations in a healthy population.</p><p><strong>Methods</strong></p><p>Lithium-heparin plasma samples were collected from 314 healthy volunteers aged 21–85 years (59 % female). The samples were analyzed for total cTnT with Roche Elecsys high sensitivity cTnT assay and with a novel upconversion luminescence-based long cTnT assay.</p><p><strong>Results</strong></p><p>The median (25th-75th percentile) long cTnT concentration of the reference population was 2.0 (1.3–3.0) ng/l. The 99th percentile URL for the long cTnT assay was 7.3 (95 % confidence interval, 5.6–8.4) ng/l. Of the healthy population 98 % had long cTnT levels above the detection limit of the assay (0.4 ng/l). The imprecision (coefficient of variation) of the long cTnT assay at the 99th percentile URL was 5.1 %. While total cTnT was heavily associated with age, especially in the older population, long cTnT remained low regardless of age. Common comorbidities and medications were also associated with the total cTnT concentration but not with the long cTnT concentration.</p><p><strong>Conclusions</strong></p><p>The long cTnT assay fulfills the requirements for a high sensitivity cTnT assay. Healthy individuals have low long cTnT concentrations regardless of age and common comorbidities.<br></p>
dc.identifier.eissn1873-3492
dc.identifier.jour-issn0009-8981
dc.identifier.olddbid203351
dc.identifier.oldhandle10024/186378
dc.identifier.urihttps://www.utupub.fi/handle/11111/47533
dc.identifier.urlhttps://doi.org/10.1016/j.cca.2025.120419
dc.identifier.urnURN:NBN:fi-fe2025082786048
dc.language.isoen
dc.okm.affiliatedauthorTuominen, Tuulia
dc.okm.affiliatedauthorVasankari, Tuija
dc.okm.affiliatedauthorJunes, Helea
dc.okm.affiliatedauthorSalonen, Selma
dc.okm.affiliatedauthorTeppo, Konsta
dc.okm.affiliatedauthorLinko-Parvinen, Anna-Maria
dc.okm.affiliatedauthorAiraksinen, Juhani
dc.okm.affiliatedauthorWittfooth, Saara
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier BV
dc.publisher.countryNetherlandsen_GB
dc.publisher.countryAlankomaatfi_FI
dc.publisher.country-codeNL
dc.relation.articlenumber120419
dc.relation.doi10.1016/j.cca.2025.120419
dc.relation.ispartofjournalClinica Chimica Acta
dc.relation.volume576
dc.source.identifierhttps://www.utupub.fi/handle/10024/186378
dc.titleLong cardiac troponin T forms in a healthy reference population
dc.year.issued2025

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S0009898125002980-main.pdf
Size:
846.66 KB
Format:
Adobe Portable Document Format