Validation of IMPROD biparametric MRI in men with clinically suspected prostate cancer: A prospective multi-institutional trial

dc.contributor.authorIvan Jambor
dc.contributor.authorJanne Verho
dc.contributor.authorOtto Ettala
dc.contributor.authorJuha Knaapila
dc.contributor.authorPekka Taimen
dc.contributor.authorKari T. Syvänen
dc.contributor.authorAida Kiviniemi
dc.contributor.authorEsa Kähkönen
dc.contributor.authorIleana Montoya Perez
dc.contributor.authorMarjo Seppänen
dc.contributor.authorAntti Rannikko
dc.contributor.authorOuti Oksanen
dc.contributor.authorJarno Riikonen
dc.contributor.authorSanna Mari Vimpeli
dc.contributor.authorTommi Kauko
dc.contributor.authorHarri Merisaari
dc.contributor.authorMarkku Kallajoki
dc.contributor.authorTuomas Mirtti
dc.contributor.authorTarja Lamminen
dc.contributor.authorJani Saunavaara
dc.contributor.authorHannu J. Aronen
dc.contributor.authorPeter J. Boström
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=kirurgia|en=Surgery|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=lääketieteellinen tiedekunta|en=Faculty of Medicine|
dc.contributor.organizationfi=tietojenkäsittelytiede|en=Computer Science|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.13290506867
dc.contributor.organization-code1.2.246.10.2458963.20.23479734818
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code1.2.246.10.2458963.20.97295082107
dc.contributor.organization-code2607100
dc.contributor.organization-code2607302
dc.contributor.organization-code2607303
dc.contributor.organization-code2607309
dc.converis.publication-id41684321
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/41684321
dc.date.accessioned2022-10-27T12:09:01Z
dc.date.available2022-10-27T12:09:01Z
dc.description.abstract<p>Background: Magnetic resonance imaging (MRI) combined with targeted biopsy (TB) is increasingly used in men with clinically suspected prostate cancer (PCa), but the long acquisition times, high costs, and inter-center/reader variability of routine multiparametric prostate MRI limit its wider adoption.</p><p>Methods and findings: The aim was to validate a previously developed unique MRI acquisition and reporting protocol, IMPROD biparametric MRI (bpMRI) (NCT01864135), in men with a clinical suspicion of PCa in a multi-institutional trial (NCT02241122). IMPROD bpMRI has average acquisition time of 15 minutes (no endorectal coil, no intravenous contrast use) and consists of T2-weighted imaging and 3 separate diffusion-weighed imaging acquisitions. Between February 1, 2015, and March 31, 2017, 364 men with a clinical suspicion of PCa were enrolled at 4 institutions in Finland. Men with an equivocal to high suspicion (IMPROD bpMRI Likert score 3-5) of PCa had 2 TBs of up to 2 lesions followed by a systematic biopsy (SB). Men with a low to very low suspicion (IMPROD bpMRI Likert score 1-2) had only SB. All data and protocols are freely available. The primary outcome of the trial was diagnostic accuracy-including overall accuracy, sensitivity, specificity, negative predictive value (NPV), and positive predictive value-of IMPROD bpMRI for clinically significant PCa (SPCa), which was defined as a Gleason score >= 3 + 4 (Gleason grade group 2 or higher). In total, 338 (338/364, 93%) prospectively enrolled men completed the trial. The accuracy and NPV of IMPROD bpMRI for SPCa were 70% (113/161) and 95% (71/75) (95% CI 87%-98%), respectively. Restricting the biopsy to men with equivocal to highly suspicious IMPROD bpMRI findings would have resulted in a 22% (75/338) reduction in the number of men undergoing biopsy while missing 4 (3%, 4/146) men with SPCa. The main limitation is uncertainty about the true PCa prevalence in the study cohort, since some of the men may have PCa despite having negative biopsy findings.</p><p>Conclusions: IMPROD bpMRI demonstrated a high NPV for SPCa in men with a clinical suspicion of PCa in this prospective multi-institutional clinical trial.</p>
dc.identifier.eissn1549-1676
dc.identifier.jour-issn1549-1277
dc.identifier.olddbid173521
dc.identifier.oldhandle10024/156615
dc.identifier.urihttps://www.utupub.fi/handle/11111/32446
dc.identifier.urnURN:NBN:fi-fe2021042822274
dc.language.isoen
dc.okm.affiliatedauthorJambor, Ivan
dc.okm.affiliatedauthorVerho, Janne
dc.okm.affiliatedauthorEttala, Otto
dc.okm.affiliatedauthorKnaapila, Juha
dc.okm.affiliatedauthorTaimen, Pekka
dc.okm.affiliatedauthorSyvänen, Kari
dc.okm.affiliatedauthorSteiner, Aida
dc.okm.affiliatedauthorKähkönen, Esa
dc.okm.affiliatedauthorMontoya Perez, Ileana
dc.okm.affiliatedauthorKauko, Tommi
dc.okm.affiliatedauthorMerisaari, Harri
dc.okm.affiliatedauthorKallajoki, Markku
dc.okm.affiliatedauthorLamminen, Tarja
dc.okm.affiliatedauthorSaunavaara, Jani
dc.okm.affiliatedauthorAronen, Hannu
dc.okm.affiliatedauthorBoström, Peter
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3122 Cancersen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3122 Syöpätauditfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherPUBLIC LIBRARY SCIENCE
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumberARTN e1002813
dc.relation.doi10.1371/journal.pmed.1002813
dc.relation.ispartofjournalPLoS Medicine
dc.relation.issue6
dc.relation.volume16
dc.source.identifierhttps://www.utupub.fi/handle/10024/156615
dc.titleValidation of IMPROD biparametric MRI in men with clinically suspected prostate cancer: A prospective multi-institutional trial
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
JamborEtAlValidationOf IMPROD.pdf
Size:
858.23 KB
Format:
Adobe Portable Document Format
Description:
Publisher's pdf