Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers

dc.contributor.authorKristin Suorsa
dc.contributor.authorAnna Pulakka
dc.contributor.authorTuija Leskinen
dc.contributor.authorJaana Pentti
dc.contributor.authorAndreas Holtermann
dc.contributor.authorOlli J. Heinonen
dc.contributor.authorJuha Sunikka
dc.contributor.authorJussi Vahtera
dc.contributor.authorSari Stenholm
dc.contributor.organizationfi=kansanterveystiede|en=Public Health|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.94792640685
dc.converis.publication-id48509458
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/48509458
dc.date.accessioned2022-10-28T12:43:09Z
dc.date.available2022-10-28T12:43:09Z
dc.description.abstract<p>Background: The accuracy of wrist-worn accelerometers in identifying sedentary time has been scarcely studied in free-living conditions. The aim of this study was to compare daily sedentary time estimates between a thigh-worn accelerometer, which measured sitting and lying postures, and a wrist-worn accelerometer, which measured low levels of movement. Methods: The study population consisted of 259 participants (Mage = 62.8 years, SD = 0.9) from the Finnish Retirement and Aging Study (FIREA). Participants wore an Axivity AX3 accelerometeron their mid-thigh and an Actigraph wActiSleep-BT accelerometer on their non-dominant wrist simultaneously for a minimum of 4 days in free-living conditions. Two definitions to estimate daily sedentary time were used for data from the wrist-worn accelerometer: 1) the count cutpoint, ≤1853 counts per minute; and 2) the Euclidean Norm Minus One (ENMO) cutpoint, <30 mg. Results: Compared to the thigh-wornaccelerometer, daily sedentary time estimate was 63 min (95% confidence interval [CI] = −53 to −73) lower by the count cutpoint and 50 min (95% CI = 34 to 67) lower by the ENMO cutpoint. The limits of agreement in daily sedentary time estimates between the thigh- and cutpoint methods for wrist-worn accelerometers were wide (the count cutpoint: −117 to 243, the ENMO cutpoint: −212 to 313 min). Conclusions: Currently established cutpoint-based methods to estimate sedentary time from wrist-worn accelerometers result in underestimation of daily sedentary time compared to posture-based estimates of thigh-worn accelerometers. Thus, sedentary time estimates obtained from wrist-worn accelerometers using currently available cutpoint-based methods should be interpreted with caution and future work is needed to improve their accuracy.<br /></p>
dc.format.pagerange234
dc.format.pagerange243
dc.identifier.jour-issn2575-6605
dc.identifier.olddbid178467
dc.identifier.oldhandle10024/161561
dc.identifier.urihttps://www.utupub.fi/handle/11111/43904
dc.identifier.urlhttps://doi.org/10.1123/jmpb.2019-0052
dc.identifier.urnURN:NBN:fi-fe2021042826234
dc.language.isoen
dc.okm.affiliatedauthorSuorsa, Kristin
dc.okm.affiliatedauthorPulakka, Anna
dc.okm.affiliatedauthorLeskinen, Tuija
dc.okm.affiliatedauthorPentti, Jaana
dc.okm.affiliatedauthorHeinonen, Olli
dc.okm.affiliatedauthorVahtera, Jussi
dc.okm.affiliatedauthorStenholm, Sari
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3142 Public health care science, environmental and occupational healthen_GB
dc.okm.discipline3142 Kansanterveystiede, ympäristö ja työterveysfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherHuman Kinetics Journals
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1123/jmpb.2019-0052
dc.relation.ispartofjournalJournal for the Measurement of Physical Behaviour
dc.relation.issue3
dc.relation.volume3
dc.source.identifierhttps://www.utupub.fi/handle/10024/161561
dc.titleComparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Journal for the Measurement of Physical Behaviour] Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers.pdf
Size:
533.1 KB
Format:
Adobe Portable Document Format
Description:
Publisher's version