Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers
| dc.contributor.author | Kristin Suorsa | |
| dc.contributor.author | Anna Pulakka | |
| dc.contributor.author | Tuija Leskinen | |
| dc.contributor.author | Jaana Pentti | |
| dc.contributor.author | Andreas Holtermann | |
| dc.contributor.author | Olli J. Heinonen | |
| dc.contributor.author | Juha Sunikka | |
| dc.contributor.author | Jussi Vahtera | |
| dc.contributor.author | Sari Stenholm | |
| dc.contributor.organization | fi=kansanterveystiede|en=Public Health| | |
| dc.contributor.organization | fi=kliininen laitos|en=Department of Clinical Medicine| | |
| dc.contributor.organization | fi=tyks, vsshp|en=tyks, varha| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.61334543354 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.94792640685 | |
| dc.converis.publication-id | 48509458 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/48509458 | |
| dc.date.accessioned | 2022-10-28T12:43:09Z | |
| dc.date.available | 2022-10-28T12:43:09Z | |
| dc.description.abstract | <p>Background: The accuracy of wrist-worn accelerometers in identifying sedentary time has been scarcely studied in free-living conditions. The aim of this study was to compare daily sedentary time estimates between a thigh-worn accelerometer, which measured sitting and lying postures, and a wrist-worn accelerometer, which measured low levels of movement. Methods: The study population consisted of 259 participants (Mage = 62.8 years, SD = 0.9) from the Finnish Retirement and Aging Study (FIREA). Participants wore an Axivity AX3 accelerometeron their mid-thigh and an Actigraph wActiSleep-BT accelerometer on their non-dominant wrist simultaneously for a minimum of 4 days in free-living conditions. Two definitions to estimate daily sedentary time were used for data from the wrist-worn accelerometer: 1) the count cutpoint, ≤1853 counts per minute; and 2) the Euclidean Norm Minus One (ENMO) cutpoint, <30 mg. Results: Compared to the thigh-wornaccelerometer, daily sedentary time estimate was 63 min (95% confidence interval [CI] = −53 to −73) lower by the count cutpoint and 50 min (95% CI = 34 to 67) lower by the ENMO cutpoint. The limits of agreement in daily sedentary time estimates between the thigh- and cutpoint methods for wrist-worn accelerometers were wide (the count cutpoint: −117 to 243, the ENMO cutpoint: −212 to 313 min). Conclusions: Currently established cutpoint-based methods to estimate sedentary time from wrist-worn accelerometers result in underestimation of daily sedentary time compared to posture-based estimates of thigh-worn accelerometers. Thus, sedentary time estimates obtained from wrist-worn accelerometers using currently available cutpoint-based methods should be interpreted with caution and future work is needed to improve their accuracy.<br /></p> | |
| dc.format.pagerange | 234 | |
| dc.format.pagerange | 243 | |
| dc.identifier.jour-issn | 2575-6605 | |
| dc.identifier.olddbid | 178467 | |
| dc.identifier.oldhandle | 10024/161561 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/43904 | |
| dc.identifier.url | https://doi.org/10.1123/jmpb.2019-0052 | |
| dc.identifier.urn | URN:NBN:fi-fe2021042826234 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Suorsa, Kristin | |
| dc.okm.affiliatedauthor | Pulakka, Anna | |
| dc.okm.affiliatedauthor | Leskinen, Tuija | |
| dc.okm.affiliatedauthor | Pentti, Jaana | |
| dc.okm.affiliatedauthor | Heinonen, Olli | |
| dc.okm.affiliatedauthor | Vahtera, Jussi | |
| dc.okm.affiliatedauthor | Stenholm, Sari | |
| dc.okm.affiliatedauthor | Dataimport, tyks, vsshp | |
| dc.okm.discipline | 3142 Public health care science, environmental and occupational health | en_GB |
| dc.okm.discipline | 3142 Kansanterveystiede, ympäristö ja työterveys | fi_FI |
| dc.okm.internationalcopublication | international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Human Kinetics Journals | |
| dc.publisher.country | United States | en_GB |
| dc.publisher.country | Yhdysvallat (USA) | fi_FI |
| dc.publisher.country-code | US | |
| dc.relation.doi | 10.1123/jmpb.2019-0052 | |
| dc.relation.ispartofjournal | Journal for the Measurement of Physical Behaviour | |
| dc.relation.issue | 3 | |
| dc.relation.volume | 3 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/161561 | |
| dc.title | Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers | |
| dc.year.issued | 2020 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Journal for the Measurement of Physical Behaviour] Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers.pdf
- Size:
- 533.1 KB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's version