Polymerization shrinkage stress of contemporary dental composites: Comparison of two measurement methods
| dc.contributor.author | Szczesio-Wlodarczyk Agata | |
| dc.contributor.author | Garoushi Sufyan | |
| dc.contributor.author | Vallittu Pekka | |
| dc.contributor.author | Bociong Kinga | |
| dc.contributor.author | Lassila Lippo | |
| dc.contributor.organization | fi=hammaslääketieteen laitos|en=Institute of Dentistry| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.64787032594 | |
| dc.converis.publication-id | 381030511 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/381030511 | |
| dc.date.accessioned | 2025-08-27T21:30:42Z | |
| dc.date.available | 2025-08-27T21:30:42Z | |
| dc.description.abstract | <p>The aim of this study was to compare two testing methodologies employed for assessing the polymerization shrinkage stress of dental resin composites. Ten commercial resin composites were investigated (EverX Posterior & Flow; G-ænial Anterior, Posterior, A'CHORD & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR flow+ and Aura Bulk Fill). Photoelastic and contraction forces measurement methods were performed. The slope of the linear trendline and C-factor of specimens were calculated. The shrinkage stress values (range between: 6.4-13.4 MPa) obtained by the photoelastic method were higher for all resin composites than the values obtained by contraction forces measurements (range between 1.2-4.8 MPa). However, there was a strong linear correlation between these methods (r=0.8). The use of both investigated methods revealed important information about the shrinkage behavior of the restorative resin composites.<br></p> | |
| dc.format.pagerange | 155 | |
| dc.format.pagerange | 163 | |
| dc.identifier.eissn | 1881-1361 | |
| dc.identifier.jour-issn | 0287-4547 | |
| dc.identifier.olddbid | 200532 | |
| dc.identifier.oldhandle | 10024/183559 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/44675 | |
| dc.identifier.url | https://doi.org/10.4012/dmj.2023-192 | |
| dc.identifier.urn | URN:NBN:fi-fe2025082785042 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Garoushi, Sufyan | |
| dc.okm.affiliatedauthor | Vallittu, Pekka | |
| dc.okm.affiliatedauthor | Lassila, Lippo | |
| dc.okm.discipline | 313 Dentistry | en_GB |
| dc.okm.discipline | 313 Hammaslääketieteet | fi_FI |
| dc.okm.internationalcopublication | international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Japanese Society for Dental Materials and Devices | |
| dc.publisher.country | Japan | en_GB |
| dc.publisher.country | Japani | fi_FI |
| dc.publisher.country-code | JP | |
| dc.relation.doi | 10.4012/dmj.2023-192 | |
| dc.relation.ispartofjournal | Dental Materials Journal | |
| dc.relation.issue | 2 | |
| dc.relation.volume | 43 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/183559 | |
| dc.title | Polymerization shrinkage stress of contemporary dental composites: Comparison of two measurement methods | |
| dc.year.issued | 2024 |