Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement

dc.contributor.authorMäntymäki H
dc.contributor.authorLankinen P
dc.contributor.authorVahlberg T
dc.contributor.authorReito A
dc.contributor.authorEskelinen A
dc.contributor.authorMäkelä K
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607310
dc.converis.publication-id40256266
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/40256266
dc.date.accessioned2022-10-28T13:05:07Z
dc.date.available2022-10-28T13:05:07Z
dc.description.abstractBackground and purpose - Whole blood (WB) cobalt (Co) and chromium (Cr) ion levels have a major role in the follow-up of metal-on-metal total hip replacement (MoM THR). We investigated, first, if there was a change in WB Co or Cr levels over repeated measurements in patients with ReCap-M2A-Magnum THR, and, second, determined how many patients had WB Co or Cr levels that exceeded the safe upper limits (SUL) in the repeated whole blood metal ion assessment. Patients and methods - A Recap-M2A-Magnum THR was used in 1,329 operations (1,188 patients) at our institution between 2005 and 2012. We identified all patients (n = 319) with unilateral ReCap-M2A-Magnum implants who had undergone at least 2 repeated metal ion measurements with the first blood sample taken mean 5.5 years (1.8-9.3) after surgery and the second taken mean 2 years (0.5-3) after the first. Results - The median WB Co and Cr ion levels decreased in repeated measurements from 1.40 (0.40-63) ppb to 1.10 (0.20-68) ppb and from 1.60 (0.60-13.0) ppb to 1.10 (0.30-19.0) ppb, respectively. 7% of the Co ion values exceeded SUL at the initial measurement, and 7% at the control measurement. The proportion of Cr ion values exceeding the safe upper limit (SUL) decreased during the measurement interval from 5% to 4%. Interpretation - Repeated metal ion measurements in unilateral ReCap-M2A-Magnum patients in a mean 2-year time interval did not show any increase. Long-term ion levels are, however, not yet known.
dc.format.pagerange243
dc.format.pagerange248
dc.identifier.eissn1745-3682
dc.identifier.jour-issn1745-3674
dc.identifier.olddbid179592
dc.identifier.oldhandle10024/162686
dc.identifier.urihttps://www.utupub.fi/handle/11111/37294
dc.identifier.urnURN:NBN:fi-fe2021042821115
dc.language.isoen
dc.okm.affiliatedauthorMäntymäki, Heikki
dc.okm.affiliatedauthorLankinen, Petteri
dc.okm.affiliatedauthorVahlberg, Tero
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherTAYLOR & FRANCIS LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1080/17453674.2019.1595469
dc.relation.ispartofjournalActa Orthopaedica
dc.relation.issue3
dc.relation.volume90
dc.source.identifierhttps://www.utupub.fi/handle/10024/162686
dc.titleRepeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Repeated cobalt and chromium.pdf
Size:
902.38 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF