Effect of ethylene oxide unit number in bis-EMA on the physical properties of additive-manufactured occlusal splint material

dc.contributor.authorWada, Junichiro
dc.contributor.authorHeponiemi, Paulina
dc.contributor.authorWada, Kanae
dc.contributor.authorGaroushi, Sufyan
dc.contributor.authorWakabayashi, Noriyuki
dc.contributor.authorIwamoto, Tsutomu
dc.contributor.authorVallittu, Pekka K
dc.contributor.authorLassila Lippo
dc.contributor.organizationfi=Turun kliininen biomateriaalikeskus (TCBC)|en=Turku Clinical Biomaterials Centre - TCBC |
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.contributor.organization-code2607500
dc.contributor.organization-code2607511
dc.converis.publication-id380942556
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/380942556
dc.date.accessioned2025-08-28T01:30:53Z
dc.date.available2025-08-28T01:30:53Z
dc.description.abstract<p><strong>Purpose: </strong>To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints.</p><p><strong>Methods: </strong>Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water. Flexural strength (FS), flexural modulus (FM), fracture toughness (FT), microwear depth (MD), degree of conversion (DC), water sorption (WSP), water solubility (WSL), color difference between non-aged and aged series (ΔE), and translucency (TP) were evaluated. All the evaluated properties other than FS and MD were analyzed by 1-way ANOVA and Tukey's post hoc analysis, while FS and MD were analyzed by Kruskal-Wallis's test and Bonferroni correction (α=0.05).</p><p><strong>Results: </strong>BE10-80% revealed the lowest FS (P < 0.01 for BE10-0%, -20%, and -30%) and FM (P < 0.01, for all), while revealing the highest DC, WSP, WSL (P < 0.01 for all) and TP (P < 0.01 for all other than BE10-60%). BE10-50% showed the highest FT (P < 0.01 for all). BE10-50%, -60%, and -80% revealed significantly lower ΔE than others (P < 0.01) and lower MD than BE10-0% (P < 0.05). Regardless of the BE10 content, FS, FM, and FT decreased with aging.</p><p><strong>Conclusions: </strong>The number of ethylene oxide units affects the physical properties of additively manufactured occlusal splints. The higher number of ethylene oxide units in bis-EMA enhanced the microwear</p>
dc.format.pagerange558
dc.format.pagerange567
dc.identifier.eissn1883-9207
dc.identifier.jour-issn1883-1958
dc.identifier.olddbid207651
dc.identifier.oldhandle10024/190678
dc.identifier.urihttps://www.utupub.fi/handle/11111/51120
dc.identifier.urlhttps://doi.org/10.2186/jpr.JPR_D_23_00203
dc.identifier.urnURN:NBN:fi-fe2025082787742
dc.language.isoen
dc.okm.affiliatedauthorWada, Junichiro
dc.okm.affiliatedauthorHeponiemi, Paulina
dc.okm.affiliatedauthorGaroushi, Sufyan
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier
dc.publisher.countryJapanen_GB
dc.publisher.countryJapanifi_FI
dc.publisher.country-codeJP
dc.relation.doi10.2186/jpr.JPR_D_23_00203
dc.relation.ispartofjournalJournal of Prosthodontic Research
dc.relation.issue4
dc.relation.volume68
dc.source.identifierhttps://www.utupub.fi/handle/10024/190678
dc.titleEffect of ethylene oxide unit number in bis-EMA on the physical properties of additive-manufactured occlusal splint material
dc.year.issued2024

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
advpub_JPR_D_23_00203.pdf
Size:
1.55 MB
Format:
Adobe Portable Document Format