Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty

dc.contributor.authorDavis Edward T
dc.contributor.authorRemes Ville
dc.contributor.authorVirolainen Petri
dc.contributor.authorGebuhr Peter
dc.contributor.authorVan Backle Bart
dc.contributor.authorRevell Matthew P
dc.contributor.authorKopjar Branko
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.converis.publication-id53222984
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/53222984
dc.date.accessioned2022-10-28T12:21:26Z
dc.date.available2022-10-28T12:21:26Z
dc.description.abstractBackgroundWhilst bony fixation of hip replacement has stable solutions, there remains controversy over which bearing best optimizes longevity and function. Ceramic-on-ceramic (CoC) bearing combinations are associated with lower risk of revision due to aseptic loosening and dislocation. Evidence for long-term functional outcomes of modern, 4th generation CoC bearings is limited. The aim of this study was to analyze outcomes and complications of the R3 (TM) Acetabular System (Smith & Nephew, Inc., Cordova, TN, USA) in combination with BIOLOX (R) Delta ceramic femoral head in patients undergoing primary total hip arthroplasty (THA).MethodsBetween June 2009 and May 2011, 175 patients (178 hips) were enrolled into a prospective, study at 6 sites in Europe and prospectively followed-up at 3 months and 1, 3, 5, and 7 years postoperative.ResultsTotal WOMAC score improved from 63 (range, 22-91) preoperative to 8 (range, 0-8) at 1-year follow-up and remained unchanged at 7-year follow-up. Modified Harris hip score improved from 45 (range, 10-87) preoperative to 83 (range, 25-100) at 3 months, 91 (range, 42-100) at 1 year, and 92 (range, 46, 100) at 7 years. UCLA Activity Rating Scale score improved from 3.3 (range, 1-8) preoperative to 6.2 (range, 2-8) at 1 year; it marginally declined to 5.8 (range, 3-8) at 7-year follow-up. There were 4 trochanteric fractures and 5 patients died of unrelated reasons. Three hips were revised (2 periprosthetic fractures and 1 subluxation). The 7-year cumulative survival rate was 98.3%.ConclusionClinical and functional improvements of THA with CoC bearing are maintained at 7 years postoperative.Trial registrationClinicalTrials.Gov, NCT03566082, Registered 10 January 2018-retrospectively registered,
dc.identifier.eissn1749-799X
dc.identifier.jour-issn1749-799X
dc.identifier.olddbid176076
dc.identifier.oldhandle10024/159170
dc.identifier.urihttps://www.utupub.fi/handle/11111/30871
dc.identifier.urnURN:NBN:fi-fe2021042824245
dc.language.isoen
dc.okm.affiliatedauthorVirolainen, Petri
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBMC
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberARTN 35
dc.relation.doi10.1186/s13018-020-02192-6
dc.relation.ispartofjournalJournal of Orthopaedic Surgery and Research
dc.relation.issue1
dc.relation.volume16
dc.source.identifierhttps://www.utupub.fi/handle/10024/159170
dc.titleMid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s13018-020-02192-6.pdf
Size:
938.99 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF