Mechanocardiography-Based Measurement System Indicating Changes in Heart Failure Patients during Hospital Admission and Discharge

dc.contributor.authorKoivisto Tero
dc.contributor.authorLahdenoja Olli
dc.contributor.authorHurnanen Tero
dc.contributor.authorKoskinen Juho
dc.contributor.authorJafarian Kamal
dc.contributor.authorVasankari Tuija
dc.contributor.authorJaakkola Samuli
dc.contributor.authorKiviniemi Tuomas O
dc.contributor.authorAiraksinen KE Juhani
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code2610303
dc.converis.publication-id177298590
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/177298590
dc.date.accessioned2022-12-20T03:31:46Z
dc.date.available2022-12-20T03:31:46Z
dc.description.abstract<p> Heart failure (HF) is a disease related to impaired performance of the heart and is a significant cause of mortality and treatment costs in the world. During its progression, HF causes worsening (decompensation) periods which generally require hospital care. In order to reduce the suffering of the patients and the treatment cost, avoiding unnecessary hospital visits is essential, as hospitalization can be prevented by medication. We have developed a data-collection device that includes a high-quality 3-axis accelerometer and 3-axis gyroscope and a single-lead ECG. This allows gathering ECG synchronized data utilizing seismo- and gyrocardiography (SCG, GCG, jointly mechanocardiography, MCG) and comparing the signals of HF patients in acute decompensation state (hospital admission) and compensated condition (hospital discharge). In the MECHANO-HF study, we gathered data from 20 patients, who each had admission and discharge measurements. In order to avoid overfitting, we used only features developed beforehand and selected features that were not outliers. As a result, we found three important signs indicating the worsening of the disease: an increase in signal RMS (root-mean-square) strength (across SCG and GCG), an increase in the strength of the third heart sound (S3), and a decrease in signal stability around the first heart sound (S1). The best individual feature (S3) alone was able to separate the recordings, giving 85.0% accuracy and 90.9% accuracy regarding all signals and signals with sinus rhythm only, respectively. These observations pave the way to implement solutions for patient self-screening of the HF using serial measurements. <br></p>
dc.identifier.jour-issn1424-8220
dc.identifier.olddbid190703
dc.identifier.oldhandle10024/173794
dc.identifier.urihttps://www.utupub.fi/handle/11111/31868
dc.identifier.urlhttps://www.mdpi.com/1424-8220/22/24/9781
dc.identifier.urnURN:NBN:fi-fe2022122072739
dc.language.isoen
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.affiliatedauthorLahdenoja, Olli
dc.okm.affiliatedauthorHurnanen, Tero
dc.okm.affiliatedauthorKoskinen, Juho
dc.okm.affiliatedauthorVasankari, Tuija
dc.okm.affiliatedauthorJaakkola, Samuli
dc.okm.affiliatedauthorKiviniemi, Tuomas
dc.okm.affiliatedauthorAiraksinen, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline113 Computer and information sciencesen_GB
dc.okm.discipline213 Electronic, automation and communications engineering, electronicsen_GB
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline113 Tietojenkäsittely ja informaatiotieteetfi_FI
dc.okm.discipline213 Sähkö-, automaatio- ja tietoliikennetekniikka, elektroniikkafi_FI
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumber9781
dc.relation.doi10.3390/s22249781
dc.relation.ispartofjournalSensors
dc.relation.issue24
dc.relation.volume22
dc.source.identifierhttps://www.utupub.fi/handle/10024/173794
dc.titleMechanocardiography-Based Measurement System Indicating Changes in Heart Failure Patients during Hospital Admission and Discharge
dc.year.issued2022

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
sensors-22-09781.pdf
Size:
1.5 MB
Format: