A miniaturized low power biomedical sensor node for clinical research and long term monitoring of cardiovascular signals

dc.contributor.authorJarno Tuominen
dc.contributor.authorEero Lehtonen
dc.contributor.authorMojtaba Jafari Tadi
dc.contributor.authorJuho Koskinen
dc.contributor.authorMikko Pänkäälä
dc.contributor.authorTero Koivisto
dc.contributor.organizationfi=kieli- ja puheteknologia|en=Language and Speech Technology|
dc.contributor.organizationfi=sulautettu elektroniikka|en=Embedded Electronics|
dc.contributor.organization-code1.2.246.10.2458963.20.20754768032
dc.contributor.organization-code1.2.246.10.2458963.20.47465613983
dc.contributor.organization-code2606805
dc.converis.publication-id28758726
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/28758726
dc.date.accessioned2022-10-28T13:40:37Z
dc.date.available2022-10-28T13:40:37Z
dc.description.abstract<p>We present a low power, miniaturized biomedical sensor node featuring electro-, seismo-and gyrocardiography. Measurement session can be set up and controlled over Bluetooth Low Energy interface. Acquired raw or preprocessed sensor data can be stored locally to the microSD memory card. To the best of the authors' knowledge, the presented device is the smallest reported to enable heart monitoring from the electrical and mechanical (with six degrees of freedom) viewpoint. The average power consumption of the device is less than 15mW, enabling continuous acquisition of high quality data of more than 60 hours with the used 250mAh Lithium-Polymer battery.<br /></p>
dc.identifier.eisbn978-1-4673-6853-7
dc.identifier.isbn978-1-5090-1427-9
dc.identifier.issn2379-447X
dc.identifier.olddbid183551
dc.identifier.oldhandle10024/166645
dc.identifier.urihttps://www.utupub.fi/handle/11111/31974
dc.identifier.urlhttp://ieeexplore.ieee.org/document/8050684/
dc.identifier.urnURN:NBN:fi-fe2021042718142
dc.language.isoen
dc.okm.affiliatedauthorTuominen, Jarno
dc.okm.affiliatedauthorLehtonen, Eero
dc.okm.affiliatedauthorJafari Tadi, Mojtaba
dc.okm.affiliatedauthorKoskinen, Juho
dc.okm.affiliatedauthorPänkäälä, Mikko
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.discipline113 Computer and information sciencesen_GB
dc.okm.discipline114 Physical sciencesen_GB
dc.okm.discipline213 Electronic, automation and communications engineering, electronicsen_GB
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline3141 Health care scienceen_GB
dc.okm.discipline113 Tietojenkäsittely ja informaatiotieteetfi_FI
dc.okm.discipline114 Fysiikkafi_FI
dc.okm.discipline213 Sähkö-, automaatio- ja tietoliikennetekniikka, elektroniikkafi_FI
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.discipline3141 Terveystiedefi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA4 Conference Article
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.conferenceIEEE International Symposium on Circuits and Systems
dc.relation.doi10.1109/ISCAS.2017.8050684
dc.source.identifierhttps://www.utupub.fi/handle/10024/166645
dc.titleA miniaturized low power biomedical sensor node for clinical research and long term monitoring of cardiovascular signals
dc.title.book2017 IEEE International Symposium on Circuits and Systems (ISCAS)
dc.year.issued2017

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
miniaturized.pdf
Size:
969.58 KB
Format:
Adobe Portable Document Format
Description:
Final draft