Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study

dc.contributor.authorJambor Ivan
dc.contributor.authorSteiner Aida
dc.contributor.authorPesola Marko
dc.contributor.authorGardberg Maria
dc.contributor.authorFrantzén Janek
dc.contributor.authorJokinen Pekka
dc.contributor.authorLiimatainen Timo
dc.contributor.authorMinn Heikki
dc.contributor.authorAronen Hannu
dc.contributor.authorMerisaari Harri
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=kliiniset neurotieteet|en=Clinical Neurosciences|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.74845969893
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code2607300
dc.contributor.organization-code2607303
dc.converis.publication-id387533868
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/387533868
dc.date.accessioned2025-08-27T23:01:20Z
dc.date.available2025-08-27T23:01:20Z
dc.description.abstractIn pre-clinical models of brain gliomas, Relaxation Along a Fictitious Field in second rotating frame (TRAFF2), continues wave T1rho (T1ρcw), adiabatic T1rho (T1ρadiab), and adiabatic T2rho (T2ρadiab) relaxation time mappings have demonstrated potential to non-invasively characterize brain gliomas. Our aim was to evaluate the feasibility and potential of 4 different spin lock methods at 3T to characterize primary brain glioma. 22 patients (26-72 years) with suspected primary glioma. T1ρcw was performed using pulse peak amplitude of 500Hz and pulse train durations of 40 and 80 ms while the corresponding values for T1ρadiab, T2ρadiab, TRAFF2 were 500/500/500Hz and 48 and 96, 64 and 112, 45 and 90 ms, respectively. The parametric maps were calculated using a monoexponential model. Molecular profiles were evaluated from tissue specimens obtained during the resection. The lesion regions-of-interest were segmented from high intensity FLAIR using automatic segmentation with manual refinement. Statistical descriptors from the voxel intensity values inside each lesion and radiomic features (Pyrad MRC package) were calculated. From extracted radiomics, mRMRe R package version 2.1.0 was used to select 3 features in each modality for statistical comparisons. Of the 22 patients, 10 were found to have IDH-mutant gliomas and of those 5 patients had 1p/19q codeletion group comparisons. Following correction for effects of age and gender, at least one statistical descriptor was able to differentiate between IDH and 1p/19q codeletion status for all the parametric maps. In the radiomic analysis, corner-edge detector features with Harris-Stephens filtered signal showed significant group differences in IDH and 1p/19q codeletion groups. Spin lock imaging at 3T of human glioma was feasible and various qualitative parameters derived from the parametric maps were found to have potential to differentiate IDH and 1p19q codeletion status. Future larger prospective clinical trials are warranted to evaluate these methods further.
dc.identifier.eissn1932-6203
dc.identifier.jour-issn1932-6203
dc.identifier.olddbid203229
dc.identifier.oldhandle10024/186256
dc.identifier.urihttps://www.utupub.fi/handle/11111/29352
dc.identifier.urlhttps://journals.plos.org/plosone/article?id=10.1371/journal.pone.0296958
dc.identifier.urnURN:NBN:fi-fe2025082790038
dc.language.isoen
dc.okm.affiliatedauthorJambor, Ivan
dc.okm.affiliatedauthorSteiner, Aida
dc.okm.affiliatedauthorPesola, Marko
dc.okm.affiliatedauthorGardberg, Maria
dc.okm.affiliatedauthorFrantzen, Janek
dc.okm.affiliatedauthorJokinen, Pekka
dc.okm.affiliatedauthorMinn, Heikki
dc.okm.affiliatedauthorAronen, Hannu
dc.okm.affiliatedauthorMerisaari, Harri
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3112 Neurosciencesen_GB
dc.okm.discipline3112 Neurotieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherPublic Library of Science
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumbere0296958
dc.relation.doi10.1371/journal.pone.0296958
dc.relation.ispartofjournalPLoS ONE
dc.relation.issue4
dc.relation.volume19
dc.source.identifierhttps://www.utupub.fi/handle/10024/186256
dc.titleRelaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study
dc.year.issued2024

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
journal.pone.0296958.pdf
Size:
906.54 KB
Format:
Adobe Portable Document Format