Randomized trial of smartphone application and bed sensor for atrial fibrillation detection in high-risk patients

dc.contributor.authorLehto, Joonas
dc.contributor.authorNuotio, Joel
dc.contributor.authorRelander, Arto
dc.contributor.authorJaakkola, Jussi
dc.contributor.authorLahdenoja, Olli
dc.contributor.authorVasankari, Tuija
dc.contributor.authorAnzanpour, Arman
dc.contributor.authorElnaggar, Ismail
dc.contributor.authorRekola, Rami
dc.contributor.authorSandelin, Jonas
dc.contributor.authorHurnanen, Tero
dc.contributor.authorAiraksinen, Juhani K. E.
dc.contributor.authorKoivisto, Tero
dc.contributor.authorKiviniemi, Tuomas O.
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.contributor.organization-code2610303
dc.converis.publication-id515606661
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/515606661
dc.date.accessioned2026-04-24T20:17:38Z
dc.description.abstract<p>This two-arm single-center exploratory randomized controlled trial evaluated the efficacy of prolonged rhythm monitoring in atrial fibrillation (AF) detection after an invasive cardiac procedure. Altogether 150 patients were enrolled. In the intervention group (IG), a bed sensor (EMFIT QS) and twice-daily smartphone recordings (CardioSignal app) were used, followed by a 12-lead ECG and a continuous three-to-seven-day ECG monitoring if alerts occurred. The control group (CG) received usual care. Overall, 78 patients were assigned to the IG and 72 to CG. During the three-month follow-up, AF was detected in 6/78 (7.7%) patients in the IG and in 0/72 (0.0%) in the CG (absolute risk difference 7.7%, 95% CI 1.8–13.6%, <em>p</em> = 0.029). After exclusion of patients who withdrew before the 3-month follow-up, 33/68 (48.5%) patients had alarms not leading to ECG-verified AF diagnosis, indicating that the current approach, in its present form, is not suitable for routine clinical implementation. Future studies should concentrate on minimizing alarms not leading to AF diagnosis when developing these novel non-ECG-based technologies. ClinicalTrials.gov Identifier: NCT05351775, 2022/04/28.<br></p>
dc.identifier.eissn2045-2322
dc.identifier.urihttps://www.utupub.fi/handle/11111/59491
dc.identifier.urlhttps://doi.org/10.1038/s41598-026-38273-5
dc.identifier.urnURN:NBN:fi-fe2026042333243
dc.language.isoen
dc.okm.affiliatedauthorLehto, Joonas
dc.okm.affiliatedauthorNuotio, Joel
dc.okm.affiliatedauthorRelander, Arto
dc.okm.affiliatedauthorJaakkola, Jussi
dc.okm.affiliatedauthorLahdenoja, Olli
dc.okm.affiliatedauthorVasankari, Tuija
dc.okm.affiliatedauthorAnzanpour, Arman
dc.okm.affiliatedauthorElnaggar, Ismail
dc.okm.affiliatedauthorRekola, Rami
dc.okm.affiliatedauthorSandelin, Jonas
dc.okm.affiliatedauthorHurnanen, Tero
dc.okm.affiliatedauthorAiraksinen, Juhani
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.affiliatedauthorKiviniemi, Tuomas
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3142 Public health care science, environmental and occupational healthen_GB
dc.okm.discipline3142 Kansanterveystiede, ympäristö ja työterveysfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer Nature
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumber7088
dc.relation.doi10.1038/s41598-026-38273-5
dc.relation.ispartofjournalScientific Reports
dc.relation.volume16
dc.titleRandomized trial of smartphone application and bed sensor for atrial fibrillation detection in high-risk patients
dc.year.issued2026

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s41598-026-38273-5.pdf
Size:
2.55 MB
Format:
Adobe Portable Document Format