A Comparison Between a Resuscitation Glove and Standard Manual Compressions on the Quality of Cardiovascular Resuscitation

dc.contributor.authorKahsay, Desale Tewelde
dc.contributor.authorTommila, Miretta
dc.contributor.authorPeltonen, Laura-Maria
dc.contributor.authorLöyttyniemi, Eliisa
dc.contributor.authorXiao, Yu
dc.contributor.authorMauranen, Henry
dc.contributor.authorSalanterä, Sanna
dc.contributor.organizationfi=anestesiologia ja tehohoito|en=Anaesthesiology, Intensive Care|
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=hoitotieteen laitos|en=Department of Nursing Science|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.27201741504
dc.contributor.organization-code1.2.246.10.2458963.20.82197219338
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.converis.publication-id491912438
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/491912438
dc.date.accessioned2026-01-21T13:40:31Z
dc.date.available2026-01-21T13:40:31Z
dc.description.abstract<p><strong>Background </strong></p><p>Several audiovisual feedback (AVF) devices have been developed to monitor chest compression quality during cardiopulmonary resuscitation (CPR). However, most marketed stand-alone AVF devices are inflexible and rigid, causing discomfort and sometimes pain to the rescuers' hands.</p><p><strong>Objective </strong></p><p>The objective of this study was to evaluate the effectiveness and usability of a newly developed soft and flexible resuscitation glove designed to improve the quality of chest compressions during CPR.</p><p><strong>Methods </strong></p><p>We conducted a manikin-based randomized crossover study to compare the effectiveness of a newly developed AVF device (ResuGlove CPR Group) and standard CPR (Standard CPR Group) in improving the quality of chest compressions in simulated cardiac arrest cases. The usability of the newly developed ResuGlove was assessed using a System Usability Scale questionnaire.</p><p><strong>Results </strong></p><p>There were no significant differences in compression depth (mean, 53.69 vs 53.28; <em>P</em> = .70) and compression rate (mean, 111.48 vs 113.38; <em>P</em> = .23) between the ResuGlove CPR and Standard CPR groups. However, the group using ResuGlove had a higher percentage of complete chest releases between compressions (<em>P</em> = .008). Furthermore, the ResuGlove CPR Group had a significantly higher percentage of participants who performed chest compressions with adequate compression depth (82.8% vs 41.4%, <em>P</em> = .001) and compression rate (96.6% vs 72.4%, <em>P</em> = .012) compared with the Standard CPR Group. The ResuGlove usability score was calculated to be 70.4.</p><p><strong>Conclusions </strong></p><p>The newly developed ResuGlove significantly improved the quality of certain chest compression parameters, and the device's usability score was within the acceptable range.<br></p>
dc.identifier.eissn1550-5049
dc.identifier.jour-issn0889-4655
dc.identifier.olddbid213234
dc.identifier.oldhandle10024/196252
dc.identifier.urihttps://www.utupub.fi/handle/11111/55016
dc.identifier.urlhttps://doi.org/10.1097/jcn.0000000000001206
dc.identifier.urnURN:NBN:fi-fe2025082792833
dc.language.isoen
dc.okm.affiliatedauthorKahsay, Desale
dc.okm.affiliatedauthorTommila, Miretta
dc.okm.affiliatedauthorPeltonen, Laura-Maria
dc.okm.affiliatedauthorLöyttyniemi, Eliisa
dc.okm.affiliatedauthorSalanterä, Sanna
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline316 Nursingen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.discipline316 Hoitotiedefi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherOvid Technologies (Wolters Kluwer Health)
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1097/JCN.0000000000001206
dc.relation.ispartofjournalJournal of Cardiovascular Nursing
dc.source.identifierhttps://www.utupub.fi/handle/10024/196252
dc.titleA Comparison Between a Resuscitation Glove and Standard Manual Compressions on the Quality of Cardiovascular Resuscitation
dc.year.issued2025

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
a_comparison_between_a_resuscitation_glove_and.285.pdf
Size:
653.25 KB
Format:
Adobe Portable Document Format