Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland

dc.contributor.authorLaurén, Jouni
dc.contributor.authorKaasalainen, Touko
dc.contributor.authorKesävuori, Risto
dc.contributor.authorNikulainen, Veikko
dc.contributor.authorSuominen, Velipekka
dc.contributor.authorHakulinen, Ullamari
dc.contributor.authorKarjalainen, Jari
dc.contributor.authorKariniemi, Juho
dc.contributor.authorVenermo, Maarit
dc.contributor.authorAho, Pekka
dc.contributor.authorFinnish Radiation Safety Collaboration Group
dc.contributor.organizationfi=kirurgia|en=Surgery|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code2607309
dc.converis.publication-id505814914
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/505814914
dc.date.accessioned2026-01-27T09:51:44Z
dc.date.available2026-01-27T09:51:44Z
dc.description.abstract<h3>Objective</h3><p>Endovascular aneurysm repair (EVAR) predisposes patients to significant radiation exposure, with well known harmful effects. This study aimed to assess the radiation doses and their consistency in Finland and to investigate the factors affecting the doses, to potentially allow future dose reductions.</p><h3>Methods</h3><p>This retrospective, nationwide, multicentre study included all patients who underwent an elective standard EVAR procedure in Finland between 2017 – 2022. Data were collected from: body mass index (BMI); fluoroscopy time (FT); radiation exposure, including kerma area product (KAP) and cumulative air kerma at the patient reference entrance point (K<sub>a,r</sub>) from fluoroscopy and digital subtraction angiography (DSA); number of DSA series; and exposure parameters of the angiography systems. Descriptive statistics and linear regression analyses were performed to identify the parameters that significantly influenced radiation exposure.</p><h3>Results</h3><p>A total of 1 185 EVAR procedures from all five centres that perform EVAR in Finland were included in the study. Large variation in medians of total procedure KAP between the centres was observed, ranging 22.5 – 135.0 Gy·cm<sup>2</sup>. Median FT ranged 16.1 – 29.1 minutes. Both fluoroscopy and DSA showed large variation in radiation exposure. BMI did not significantly differ between the centres. The factors significantly affecting the dose in the multivariate linear regression model were BMI, FT, number of DSA acquisitions, DSA frame rate, and maximum copper filtration in fluoroscopy.</p><h3>Conclusion</h3><p>Surprisingly high, up to six fold, intercentre variability in total procedure radiation exposure was observed. The variability in the doses was mostly attributable to differences in exposure parameters (e.g., dose at detector level, copper filtration, and pulse rate); the manner in which radiation is utilised also played a significant role. In other words, both angiography system parameters and the working habits of the operator need to be optimised.</p>
dc.identifier.eissn1532-2165
dc.identifier.jour-issn1078-5884
dc.identifier.olddbid214305
dc.identifier.oldhandle10024/197323
dc.identifier.urihttps://www.utupub.fi/handle/11111/38838
dc.identifier.urlhttps://doi.org/10.1016/j.ejvs.2025.11.058
dc.identifier.urnURN:NBN:fi-fe202601215592
dc.language.isoen
dc.okm.affiliatedauthorNikulainen, Veikko
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1016/j.ejvs.2025.11.058
dc.relation.ispartofjournalEuropean Journal of Vascular and Endovascular Surgery
dc.source.identifierhttps://www.utupub.fi/handle/10024/197323
dc.titleRadiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland
dc.year.issued2025

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S107858842501202X-main.pdf
Size:
653.8 KB
Format:
Adobe Portable Document Format